plcSimulator.py
8.65 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
import os
import sys
import json
DEBUG_FILE = True
PACKAGE_PARENT = '..'
SCRIPT_DIR = os.path.dirname(os.path.realpath(os.path.join(os.getcwd(), os.path.expanduser(__file__))))
sys.path.append(os.path.normpath(os.path.join(SCRIPT_DIR, PACKAGE_PARENT)))
#(EP renamed) from utils.Device import Device
from utils.DeviceSim import DeviceSim
from utils.StatusManager import StatusManager
#(EP renamed) class PLCSimulator(Device, StatusManager):
class PLCSimulator(DeviceSim, StatusManager):
# (EP) This simulator will generate some events ?
EVENT_GENERATOR=False
status = {
"name": "STATUS", "from": "Beckhoff", "version_firmware": "20170809", "site": "OSM-Mexico",
"date": "2017-03-03T13:45:00",
"device": [{"name": "WXT520", "type": "meteo", "serial_number": "14656423", "valid": "yes",
"values": [
{"name": "OutsideTemp", "value": 12.12, "unit": "Celcius", "comment": ""},
{"name": "OutsideHumidity", "value": 64.1, "unit": "percent", "comment": ""},
{"name": "Pressure", "value": 769.2, "unit": "mbar", "comment": "At site elevation"},
{"name": "RainRate", "value": 0.0, "unit": "mm/h", "comment": ""},
{"name": "WindSpeed", "value": 3.1, "unit": "m/s", "comment": ""},
{"name": "WindDir", "value": 202.3, "unit": "deg", "comment": "(N=0, E=90)"},
{"name": "DewPoint", "value": 8.3, "unit": "deg", "comment": ""}
]
},
{"name": "DRD11", "type": "meteo", "serial_number": "RET6789", "valid": "yes",
"values": [
{"name": "analog", "value": 2.345, "unit": "V", "comment": "3V=Dry <2.5V=Rain"},
{"name": "digital", "value": 1, "unit": "bool", "comment": "1=Dry 0=Rain"}
]
},
{"name": "VantagePro", "type": "meteo", "serial_number": "ERTRY2344324", "valid": "no",
"values": [
{"name": "OutsideTemp", "value": 12.45, "unit": "Celcius", "comment": ""},
{"name": "InsideTemp", "value": 20.28, "unit": "Celcius", "comment": ""},
{"name": "OutsideHumidity", "value": 65.3, "unit": "percent", "comment": ""},
{"name": "InsideHumidity", "value": 45.6, "unit": "percent", "comment": ""},
{"name": "Pressure", "value": 768.7, "unit": "mbar", "comment": "At site elevation"},
{"name": "RainRate", "value": 0.0, "unit": "mm/h", "comment": ""},
{"name": "WindSpeed", "value": 2.8, "unit": "m/s", "comment": ""},
{"name": "WindDir", "value": 207.0, "unit": "deg", "comment": "(N=0, E=90)"},
{"name": "WindDirCardinal", "value": "SW", "unit": "string", "comment": ""},
{"name": "DewPoint", "value": 8.5, "unit": "deg", "comment": ""}
]
},
{"name": "MLX90614-1", "type": "meteo", "serial_number": "Unknown", "valid": "yes",
"values": [
{"name": "SensorTemperature", "value": 23.56, "unit": "Celcius", "comment": ""},
{"name": "SkyTemperature", "value": -15.67, "unit": "Celcius",
"comment": "Clear<-10 VeryCloudy>4"}
]
},
{"name": "LAMP_FLAT_CAGIRE", "type": "calib", "serial_number": "REF_3434", "valid": "yes",
"values": [
{"name": "status", "value": "on", "unit": "string", "comment": "on or off"},
{"name": "current", "value": 0.234, "unit": "Ampere", "comment": ""}
]
},
{"name": "LAMP FLAT CAGIRE", "type": "calib", "serial_number": "REF_3434", "valid": "yes",
"values": [
{"name": "status", "value": "on", "unit": "string", "comment": "on or off"},
{"name": "current", "value": 0.234, "unit": "Ampere", "comment": ""}
]
}
]
}
list = {"name": "LIST", "from": "Beckhoff", "version_firmware": "20170809", "site": "OSM-Mexico",
"date": "2017-03-03T13:42:46",
"command": [
{"name": "LIST", "type": "",
"parameters": ""
},
{"name": "SATUS", "type": "",
"parameters": ""
},
{"name": "LAMP_FLAT_CAGIRE", "type": "calib",
"parameters": [
{"name": "value", "unit": "string", "comment": "on or off", "default": ""},
{"name": "current", "unit": "Ampere", "comment": "", "default": "0.345"}
]
}
]
}
def __init__(self, argv):
# DeviceSim init
super().__init__(argv)
# Listen to its own ip and port (the PLC's)
self.setDevice("PLC")
#EP added
if (len(argv) > 1):
self.setStatusManager("plcSimulator", argv)
self.EVENT_GENERATOR = True
def plcPrint(self, string: str):
if DEBUG_FILE:
print("PLCSimulator : " + string)
def updateStatus(self, i: int):
for dic in self.sims:
# ex: dic is like "plcSimulator" : {"device_name":"VantagePro", "value_name":"RainRate", "value":12.0}
if (int(dic["time"]) == i):
print(dic)
change = dic[self.status_name] # ex: {"device_name":"VantagePro", "value_name":"RainRate", "value":12.0}
device_name = change["device_name"] # ex: VantagePro
devices = self.status["device"]
for device in devices:
if device["name"] == device_name:
values = device["values"]
# ex: for VantagePro
# values =
# {"name": "OutsideTemp", "value": 12.45, "unit": "Celcius", "comment": ""},
# {"name": "InsideTemp", "value": 20.28, "unit": "Celcius", "comment": ""},
#...
for value in values:
if value["name"] == change["value_name"]:
# This will indirectly update self.status
value["value"] = change["value"]
return 0
def handleConnections(self):
print("number of connexions to handle: "+str(len(self.connections)))
for conn in self.connections:
print("current connexion: ")
print(conn)
data = self.readBytes(1024, conn)
answer = "["
count = False
#if data != "" and self.isError(data) is False:
if data != "" and not self.isError(data):
json_array = json.loads(data)
command_list = json_array["command"]
for command in command_list:
if command["name"] == "STATUS":
if count:
answer += ','
answer += json.dumps(self.status)
count = True
elif command["name"] == "LIST":
if count:
answer += ','
answer += json.dumps(self.status)
count = True
else:
print("command received by PLC simulator : [>>> "+ str(command["name"]) + " <<<] unknown")
answer += ']'
if len(answer) > 0 and answer != "[]":
self.sendMessage(answer, conn)
return (0)
def loop(self):
i = 0
if (self.EVENT_GENERATOR and self.ended==0):
self.plcPrint("No entry for PLC found in config file : " + self.config_file)
return False
while (True):
print("\n\n\nIteration "+str(i)+" :")
if self.EVENT_GENERATOR: self.updateStatus(i)
if (self.isConnected()):
self.handleConnections()
i += 1
if (self.EVENT_GENERATOR and i > self.ended): return (0)
return True
def run(self):
if DEBUG_FILE:
print("PLC simulator running...")
if self.EVENT_GENERATOR and not self.parse(): return False
self.configSocket()
return self.loop()