ak_plc_controller.py
9.24 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
#!/usr/bin/env python3
"""Socket Client Gemini Telescope implementation
To be used as a concrete class to system control a Gemini telescope
"""
# Standard library imports
#import socket
#import logging
import sys
import time
# Third party imports
# None
# Local application imports
sys.path.append('../..')
#from src.client.socket_client_telescope_abstract import Position, UnknownCommandException, TimeoutException, SocketClientTelescopeAbstract
from src_device.client.plc_controller_abstract import *
# Default timeouts
TIMEOUT_SEND = 10
TIMEOUT_RECEIVE = 10
# COMMON CONSTANTS WITH SERVER
TERMINATOR = '\x00'
COMMAND5 = '050000'
#COMMAND6_SIMPLE = '\x00\x06'
COMMAND6 = '\x00\x06\x00'
COMMAND6_SIMPLE = '6'
class DeviceControllerPLCAK(DeviceControllerPLC):
# STAMP :
# 00 00 00 00 00 00 00' (8 bytes from '00' to 'FF', 1st one is LOW BYTE)
# ex: 01 + STAMP = 01 00 00 00 00 00 00 00' (8 bytes from '00' to 'FF', 1st one is LOW BYTE)
#STAMP_FILLER = '00000000000000'
#MY_FULL_STAMP = MYSTAMP + STAMP_FILLER
# Initialize request number (will be increased at each request)
request_num = 0
# Request number stands on 4 digits (from 0001 to 9999)
request_num_nb_digits = 4
# For 4 digits, we should get the format '{:04d}':
request_num_format = '{:0'+str(request_num_nb_digits)+'d}'
# Stamp filler with 0
STAMP_FILLER = '0' * (8 - request_num_nb_digits)
#data = " ".join(sys.argv[1:])
#data_to_send = bytes(data + "\n", "utf-8")
''' Commands dictionary
NEW foramt is:
'generic-command-name': ['native-command-name', 'awaited_result_if_ok', 'other-awaited-results if not ok...],
Old format was:
'CMD-NAME': ['cmd-get', 'awaited_res_ok_for_get', 'cmd-set', 'awaited_res_ok_for_set', 'comment'],
'''
# @overwrite
_cmd_native = {
# GET @ SET commands
'get_ack': [COMMAND6, 'G', 'B','b','S'], # B# while the initial startup message is being displayed (new in L4), b# while waiting for the selection of the Startup Mode, S# during a Cold Start (new in L4), G# after completed startup.
# RA-DEC (p109-110)
#:Sr<hh>:<mm>.<m># or :Sr<hh>:<mm>:<ss>#
#Sets the object's Right Ascension and the object status to "Not Selected". The :Sd# command has to follow to complete the selection. The subsequent use of the :ON...# command is recommended
#:Sd{+-}<dd>{*°}<mm># or :Sd{+- }<dd>{*°:}<mm>:<ss>
#Sets the object's declination. It is important that the :Sr# command has been send prior. Internal calculations are done that may take up to 0.5 seconds. If the coordinate selection is valid the object status is set to "Selected"
#'RADEC': [('GR','GD'), ''],
#'ra': ['GR', None, 'Sr', None, 'commentaire'],
'get_ra': ['GR'],
'set_ra': ['Sr'],
'get_dec': ['GD'],
'set_dec': ['Sd'],
# get_radec and set_radec are already defined in abstract class
'get_timezone': ['GG'],
'set_timezone': ['SG', '1'],
# ALT-AZ (p?)
"get_alt": ['GA'],
"get_az": ['GZ'],
#"ALT-AZ": [('GA','GZ'), ''],
# LONG-LAT
"get_long": ['Gg'],
"set_long": ['Sg'],
"get_lat": ['Gt'],
"set_lat": ['St'],
#"LONGLAT": [('Gg','Gt'), ''],
"get_hangle": ['GH'],
'get_vel': ['Gv'],
#"get_maxvel": ['Gv'],
'get_date': ['GC'],
'set_date': ['SC'],
'get_time': ['GL'],
'set_time': ['SL'],
# DO commands
# defined in abstract class:
#'do_init': ['do_init'],
'do_park': ['hP'],
'do_warm_start': ['bW'],
'do_prec_refr': ['p3'],
'do_move': ['MS', '0', '1Object below horizon.', '2No object selected.', '3Manual Control.', '4Position unreachable.', '5Not aligned.', '6Outside Limits.' ],
'do_movenorth': ['Mn'],
'do_movesouth': ['Ms'],
'do_movewest': ['Mw'],
'do_moveeast': ['Me'],
'do_stop': ['Q'],
}
# @overwrite
# Gemini is using UDP
def __init__(self, server_host:str="localhost", server_port:int=11110, DEBUG=False):
super().__init__(server_host, server_port, "TCP", 1024, DEBUG)
# @overwrite
def formated_cmd(self, cmd:str, values_to_set:str=None)->str:
if values_to_set != None:
for value_to_set in values_to_set:
cmd += value_to_set
if cmd not in (COMMAND6, COMMAND5):
cmd += '#'
if cmd not in ('bC#','bW#','bR#'):
cmd=':'+cmd
return cmd
# @overwrite
def encapsulate_data_to_send(self, command:str):
r''' Encapsulate useful data to be ready for sending
If data is "complete" (with stamp, and well formatted), send it as is
Otherwise, add stamp and format it
3 types of commands:
- TYPE1: '06' or '050000'
- TYPE2: ':cde#' (mainly ':??#' - i.e : ':GD#', ':GR#', ...)
- TYPE3: 'b?#' (bC# = Cold Start, bW# = selecting Warm Start, bR# = selecting Warm Restart)
:Examples:
>>> tele = SocketClientTelescopeGemini("localhost", 11110, DEBUG=False)
>>> tele.encapsulate_data_to_send(':GD#')
'00010000:GD#\x00'
>>> tele.encapsulate_data_to_send(':GR#')
'00020000:GR#\x00'
>>> tele.close()
# ne marche pas => '00010000:GD#\x00'
'''
####return bytes(self.MYSTAMP + self.STAMP_FILLER + data + "\n", "utf-8")
# TYPE1
#print("command to encapsulate is", repr(command))
if command == COMMAND6_SIMPLE: command = COMMAND6
if command not in (COMMAND6, COMMAND5):
# TYPE2 or 3
#has_starting_car = data.find(':') > -1
if len(command) < 3: raise UnknownCommandException()
if not (command[-1]=='#'): raise UnknownCommandException()
if not (command[0]==':') and command not in ('bC#','bW#','bR#'): raise UnknownCommandException()
#stamp,command = data.split(':',1)
#if command.find('#')>-1: command,_ = command.split('#',1)
self.request_num += 1
# Format to request_num_nb_digits (4) digits
request_num_str = self.request_num_format.format(self.request_num)
self.last_stamp = request_num_str + self.STAMP_FILLER
#if command == COMMAND6_SIMPLE: command = COMMAND6_REAL
return self.last_stamp + command + TERMINATOR
#return bytes(data + "\n", "utf-8")
####return bytes(self.MYSTAMP + self.STAMP_FILLER + data + "\n", "utf-8")
# @overwrite
def uncap_received_data(self, data_received_bytes:bytes)->str:
r"""
Extract useful data from received raw data
>>> tele = SocketClientTelescopeGemini("localhost", 11110, DEBUG=False)
>>> tele.last_stamp = '00170000'
>>> tele.uncap_received_data(b'001700001\x00')
'1'
>>> tele.close()
"""
#print("data_received_bytes type is", type(data_received_bytes))
#print("data received is", data_received_bytes)
#TODO: resoudre ce pb plus proprement (utiliser unicode au lieu de utf-8 codec ???
# BUGFIX: b'\xdf' (should correspond to "°" symbol) generates a UnicodeDecodeError,
# so, replace it by ':' (b'\x3A')
if b'\xdf' in data_received_bytes:
data_received_bytes = data_received_bytes.replace(b'\xdf', b'\x3A')
data_received = data_received_bytes.decode()
#print("data_received is", data_received)
# Remove STAMP (and \n at the end):
#useful_data = data_received.split(self.MY_FULL_STAMP)[1][:-1]
useful_data = data_received.split(self.last_stamp)[1][:-1]
# Remove '#' at the end, if exists
if useful_data[-1] == '#': useful_data = useful_data[:-1]
return useful_data
if __name__ == "__main__":
import doctest
doctest.testmod()
exit()
# Classic usage:
#plc_client = SocketClient_Gemini(HOST, PORT)
# More elegant usage, using "with":
with DeviceControllerPLCAK("localhost", 11110, DEBUG=False) as plc_client:
# 0) CONNECT to server (only for TCP, does nothing for UDP)
plc_client._connect_to_server()
#plc_client.config()
# Send some commands to the Telescope
#pos = plc_client.get_position()
# Do EXPERT mode execution
while True:
# 1) SEND REQUEST data to server
# saisie de la requête au clavier et suppression des espaces des 2 côtés
data = input("(EXPERT MODE) REQUEST TO SERVER [ex: ':GD#' (Get Dec), ':GR#' (Get RA)']: ").strip()
# test d'arrêt
if data == "": break
#data_to_send = bytes(data + "\n", "utf-8")
plc_client.send_data(data)
#mysock.sendto("%s" % data, (HOST, PORT))
#print("Sent: {}".format(data))
# 2) RECEIVE REPLY data from server
data_received = plc_client.receive_data()
#reponse, adr = mysock.recvfrom(buf)
#print("Received: {}".format(data_received))
#print("Useful data received: {}".format(data_useful))
print('\n')
#plc_client.close()