plcSimulator.py
12.3 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
#!/usr/bin/env python3
"""
MODIFIED:
PM 20190108
"""
import os
import sys
import json
import time
import logging
#import urllib.request
DEBUG_FILE = True
PACKAGE_PARENT = '..'
SCRIPT_DIR = os.path.dirname(os.path.realpath(os.path.join(os.getcwd(), os.path.expanduser(__file__))))
sys.path.append(os.path.normpath(os.path.join(SCRIPT_DIR, PACKAGE_PARENT)))
#(_path = os.path.abspath("..")
#(sys.path.insert(0, _path )
import logconf
logger = logging.getLogger(__name__)
#(EP renamed) from utils.Device import Device
from utils.DeviceSim import DeviceSim
from utils.StatusManager import StatusManager
#(EP renamed) class PLCSimulator(Device, StatusManager):
class PLCSimulator(DeviceSim, StatusManager):
# (EP) This simulator will generate some events ?
EVENT_GENERATOR=False
lights = "ON"
shutters = "CLOSE"
status =""
def __init__(self, argv):
# DeviceSim init
super().__init__(argv)
# Listen to its own ip and port (the PLC's)
self.setDevice("PLC")
self.loop = self.loop_3
#PM Load PLC status in colibri-new-fixed-2.json
colibri_json = open("colibri-new-fixed-2.json")
colibri_struct = json.load(colibri_json)
self.status = colibri_struct["statuses"][1]["entities"][0]
#EP added
if (len(argv) > 1):
self.setStatusManager("plcSimulator", argv)
self.EVENT_GENERATOR = True
#self.set_status()
#self.my_state.status = 'init'
def plcPrint(self, string: str):
if DEBUG_FILE:
print("PLCSimulator : " + string)
def updateStatus(self, i: int):
for dic in self.sims:
# ex: dic is like "plcSimulator" : {"device_name":"VantagePro", "value_name":"RainRate", "value":12.0}
if (int(dic["time"]) == i):
print(dic)
change = dic[self.status_name] # ex: {"device_name":"VantagePro", "value_name":"RainRate", "value":12.0}
device_name = change["device_name"] # ex: VantagePro
devices = self.status["devices"]
for device in devices:
if device["device_name"] == device_name:
values = device["device_values"]
# ex: for VantagePro
# values =
# {"name": "OutsideTemp", "value": 12.45, "unit": "Celcius", "comment": ""},
# {"name": "InsideTemp", "value": 20.28, "unit": "Celcius", "comment": ""},
#...
for value in values:
if value["name"] == change["value_name"]:
# This will indirectly update self.status
value["value"] = change["value"]
return 0
def handleConnections(self):
print("number of connexions to handle: "+str(len(self.connections)))
for conn in self.connections:
print("current connexion: ")
print(conn)
data = self.readBytes(1024, conn)
answer = "["
count = False
#if data != "" and self.isError(data) is False:
if data != "" and not self.isError(data):
json_array = json.loads(data)
command_list = json_array["command"]
for command in command_list:
if command["name"] == "STATUS":
answer = self.get_status(count, answer)
count = True
elif command["name"] == "LIST":
if count:
answer += ','
answer += json.dumps(self.status)
count = True
elif command["name"] == "SWITCH LINES ON":
self.lights = "ON"
answer = "[Lights turned on"
elif command["name"] == "SWITCH LINES OFF":
self.lights = "OFF"
answer = "[Lights turned off"
elif command["name"] == "OPEN SHUTTERS":
self.shutters = "OPEN"
answer = "[Shutters opened"
elif command["name"] == "CLOSE SHUTTERS":
self.shutters = "CLOSE"
answer = "[Shutters closed"
else:
print("command received by PLC simulator : [>>> "+ str(command["name"]) + " <<<] unknown")
answer += ']'
if len(answer) > 0 and answer != "[]":
self.sendMessage(answer, conn)
return (0)
def loop(self):
pass
def loop_3(self):
#from simulators.plc.guitalens_worker import WorkerState, WorkerUrl
from plc.guitalens_worker import WorkerState, WorkerUrl
# load guitalens_worker
self.my_state = WorkerState()
self.my_worker = WorkerUrl(self.my_state, self.status)
self.my_worker.start()
self.my_state.status = 'init'
logger.info('Enter loop_3')
while (self.my_state.worker == 'start'):
if (self.isConnected()):
self.handleConnections()
time.sleep(0.5)
logger.info('Exit loop_3')
self.my_state.worker == 'stop'
def loop_2(self):
#from simulators.plc.meteo_worker import WorkerState, WorkerLog
from plc.meteo_worker import WorkerState, WorkerLog
# load meteo_worker
self.my_state = WorkerState()
self.my_worker = WorkerLog(self.my_state, self.status)
self.my_worker.start()
self.my_state.status = 'init'
while (self.my_state.worker == 'start'):
if (self.isConnected()):
self.handleConnections()
time.sleep(0.5)
self.my_state.worker == 'stop'
return True
def loop_1(self):
if self.EVENT_GENERATOR and not self.parse(): return False
i = 0
if (self.EVENT_GENERATOR and self.ended==0):
self.plcPrint("No entry for PLC found in config file : " + self.config_file)
return False
while (True):
print("\n\n\nIteration "+str(i)+" :")
if self.EVENT_GENERATOR: self.updateStatus(i)
if (self.isConnected()):
self.handleConnections()
i += 1
if (self.EVENT_GENERATOR and i > self.ended): return (0)
return True
def run(self):
if DEBUG_FILE:
print("PLC simulator running...")
#if self.EVENT_GENERATOR and not self.parse(): return False
self.configSocket()
return self.loop()
#return (0)
# deprecated
def set_status(self):
self.status = {
"name": "STATUS", "from": "Beckhoff", "version_firmware": "20170809", "site": "OSM-Mexico",
"date": "2017-03-03T13:45:00",
"device": [{"name": "WXT520", "type": "meteo", "serial_number": "14656423", "valid": "yes",
"values": [
{"name": "OutsideTemp", "value": 12.12, "unit": "Celcius", "comment": ""},
{"name": "OutsideHumidity", "value": 64.1, "unit": "percent", "comment": ""},
{"name": "Pressure", "value": 769.2, "unit": "mbar", "comment": "At site elevation"},
{"name": "RainRate", "value": 0.0, "unit": "mm/h", "comment": ""},
{"name": "WindSpeed", "value": 3.1, "unit": "m/s", "comment": ""},
{"name": "WindDir", "value": 202.3, "unit": "deg", "comment": "(N=0, E=90)"},
{"name": "DewPoint", "value": 8.3, "unit": "deg", "comment": ""}
]
},
{"name": "DRD11", "type": "meteo", "serial_number": "RET6789", "valid": "yes",
"values": [
{"name": "analog", "value": 2.345, "unit": "V", "comment": "3V=Dry <2.5V=Rain"},
{"name": "digital", "value": 1, "unit": "bool", "comment": "1=Dry 0=Rain"}
]
},
{"name": "VantagePro", "type": "meteo", "serial_number": "ERTRY2344324", "valid": "no",
"values": [
{"name": "OutsideTemp", "value": 12.45, "unit": "Celcius", "comment": ""},
{"name": "InsideTemp", "value": 20.28, "unit": "Celcius", "comment": ""},
{"name": "OutsideHumidity", "value": 65.3, "unit": "percent", "comment": ""},
{"name": "InsideHumidity", "value": 45.6, "unit": "percent", "comment": ""},
{"name": "Pressure", "value": 768.7, "unit": "mbar", "comment": "At site elevation"},
{"name": "RainRate", "value": 0.0, "unit": "mm/h", "comment": ""},
{"name": "WindSpeed", "value": 2.8, "unit": "m/s", "comment": ""},
{"name": "WindDir", "value": 207.0, "unit": "deg", "comment": "(N=0, E=90)"},
{"name": "WindDirCardinal", "value": "SW", "unit": "string", "comment": ""},
{"name": "DewPoint", "value": 8.5, "unit": "deg", "comment": ""}
]
},
{"name": "MLX90614-1", "type": "meteo", "serial_number": "Unknown", "valid": "yes",
"values": [
{"name": "SensorTemperature", "value": 23.56, "unit": "Celcius", "comment": ""},
{"name": "SkyTemperature", "value": -15.67, "unit": "Celcius",
"comment": "Clear<-10 VeryCloudy>4"}
]
},
{"name": "LAMP_FLAT_CAGIRE", "type": "calib", "serial_number": "REF_3434", "valid": "yes",
"values": [
{"name": "status", "value": "on", "unit": "string", "comment": "on or off"},
{"name": "current", "value": 0.234, "unit": "Ampere", "comment": ""}
]
},
{"name": "LAMP FLAT CAGIRE", "type": "calib", "serial_number": "REF_3434", "valid": "yes",
"values": [
{"name": "status", "value": "on", "unit": "string", "comment": "on or off"},
{"name": "current", "value": 0.234, "unit": "Ampere", "comment": ""}
]
},
{"name": "GLOBAL",
"values": [
{"name": "mode", "value": "AUTO", "unit": "String", "comment": "AUTO OFF MANU"},
{"name": "is_safe", "value": True, "unit": "bool", "comment": "True or False"},
{"name": "LIGHTS", "value": self.lights, "unit": "String", "comment": "ON or OFF"},
{"name": "SHUTTERS", "value": self.shutters, "unit": "String", "comment": "OPEN OR CLOSE"},
]
}
],
}
'''
Si on veut rajouter des éléments dans les json il faut penser a ajouter les méthodes correspondantes dans models.py
'''
def get_status(self, count, answer):
"""list = {"name": "LIST", "from": "Beckhoff", "version_firmware": "20170809", "site": "OSM-Mexico",
"date": "2017-03-03T13:42:46",
"command": [
{"name": "LIST", "type": "",
"parameters": ""
},
{"name": "SATUS", "type": "",
"parameters": ""
},
{"name": "LAMP_FLAT_CAGIRE", "type": "calib",
"parameters": [
{"name": "value", "unit": "string", "comment": "on or off", "default": ""},
{"name": "current", "unit": "Ampere", "comment": "", "default": "0.345"}
]
}
]
}"""
if count:
answer += ','
answer += json.dumps(self.status)
return answer
if __name__ == "__main__":
sim = PLCSimulator(sys.argv)
sim.run()