canconnect.pro
5.23 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
;+
; NAME:
; CANCONNECT
;
; PURPOSE:
;
; This function will check to see if it is possible to make
; a connection with the window system. It is useful when
; running IDL as a CRON job or from remote logins. The program
; will establish a system variable named !FSC_Display_Connection the
; first time it is run. Programs which need to know if a connection
; can be established can consult this system variable as a faster
; way of determining a connection than running this program. The
; system variable is set to 1 if a connection can be made and to
; 0 otherwise.
;
; AUTHOR:
;
; FANNING SOFTWARE CONSULTING
; David Fanning, Ph.D.
; 1645 Sheely Drive
; Fort Collins, CO 80526 USA
; Phone: 970-221-0438
; E-mail: david@idlcoyote.com
; Coyote's Guide to IDL Programming: http://www.idlcoyote.com
;
; CATEGORY:
; Utilities
;
; CALLING SEQUENCE:
;
; connection = CanConnect()
;
; RETURN_VALUE:
;
; connection: Will be set to 1 if a window connection is possible
; Otherwise, it will be set to 0.
;
; INPUT_PARAMETERS:
;
; None.
;
; KEYWORDS:
;
; None.
;
; NOTES:
;
; A system variable, !FSC_Display_Connection is created.
;
; MODIFICATION HISTORY:
;
; Written by David W. Fanning, 10 February 2010.
; Modified program to set the system variable !FSC_Display_Connection. This is primarily
; a way for legacy code to run in cron jobs without continually checking for
; a connection, which before this update required opening and closing a window.
; 7 October 2010. DWF.
;-
;******************************************************************************************;
; Copyright (c) 2010, by Fanning Software Consulting, Inc. ;
; All rights reserved. ;
; ;
; Redistribution and use in source and binary forms, with or without ;
; modification, are permitted provided that the following conditions are met: ;
; ;
; * Redistributions of source code must retain the above copyright ;
; notice, this list of conditions and the following disclaimer. ;
; * Redistributions in binary form must reproduce the above copyright ;
; notice, this list of conditions and the following disclaimer in the ;
; documentation and/or other materials provided with the distribution. ;
; * Neither the name of Fanning Software Consulting, Inc. nor the names of its ;
; contributors may be used to endorse or promote products derived from this ;
; software without specific prior written permission. ;
; ;
; THIS SOFTWARE IS PROVIDED BY FANNING SOFTWARE CONSULTING, INC. ''AS IS'' AND ANY ;
; EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES ;
; OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT ;
; SHALL FANNING SOFTWARE CONSULTING, INC. BE LIABLE FOR ANY DIRECT, INDIRECT, ;
; INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED ;
; TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; ;
; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ;
; ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT ;
; (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS ;
; SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. ;
;******************************************************************************************;
Function CanConnect
; Assume a good connection.
haveConnection = 1
; Try to open a window. If you fail, you have no window connection.
Catch, theError
IF theError NE 0 THEN BEGIN
Catch, /CANCEL
haveConnection = 0
GOTO, cleanUp
ENDIF
; Try to open a window.
theWindow = !D.Window
Window, /FREE, XSIZE=5, YSIZE=5, /PIXMAP
Catch, /CANCEL
; Come here if things go south or you actually make it here.
cleanUp:
IF !D.Window NE theWindow THEN BEGIN
WDelete, !D.Window
IF theWindow GE 0 THEN WSet, theWindow
ENDIF
; Does the system variable !FSC_Display_Connection exist? If so, set its value.
; If not, create it.
DefSysV, '!FSC_Display_Connection', EXISTS=sysvarExists
IF sysvarExists $
THEN !FSC_Display_Connection = haveConnection $
ELSE DefSysV, '!FSC_Display_Connection', haveConnection
RETURN, haveConnection
END