Commit d8e1c617e22765bbeff0c3cc7f4230a852278787

Authored by Quentin Brzustowski
1 parent 02db57b3

Added Descriptions of Magnetometers for AMPTE - CCE, IRM and UKS

Instrument/CDPP-AMDA/CCE/MAG.xml 0 → 100644
... ... @@ -0,0 +1,37 @@
  1 +<?xml version="1.0" encoding="UTF-8"?>
  2 +<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://amda.irap.omp.eu/public/schemas/spase-2_3_1.xsd">
  3 + <Version>2.2.6</Version>
  4 + <Instrument>
  5 + <ResourceID>spase://CNES/Instrument/CDPP-AMDA/CCE/MAG</ResourceID>
  6 + <ResourceHeader>
  7 + <ResourceName>AMPTE-CCE MAG</ResourceName>
  8 + <AlternateName>Magnetic Field Experiment (MFE)</AlternateName>
  9 + <ReleaseDate>2019-05-05T12:34:56Z</ReleaseDate>
  10 + <Description>The Magnetic Field Experiment (MFE) includes a fluxgate magnetometer sensor mounted on a 2.3 m boom.
  11 + The fluxgate sensor was sampled at a rate of 8 vector samples/s. It had seven automatically switchable ranges (from +/- 16 nT to +/- 65,536 nT) with resolution
  12 + commensurate with a 13-bit A/D converter, and was read out at 8.6 vector samples/s. The signals from two sensors
  13 + (one parallel to the spin axis and one orthogonal) were also fed into 5-50 Hz bandpass channels that were read out every 5 s.
  14 + The data span the entire AMPTE-CCE mission, from 1984 day 234, August 21, through 1989 day 009 with occasional data gaps.
  15 + A lengthy data gap occurred in 1986 from day 252, September 9 through day 286, October 12, during an extended eclipse period.
  16 + </Description>
  17 + <Acknowledgement>User will acknowledge the AMPTE/CCE magnetometer team in any publication resulting from the use of these data.</Acknowledgement>
  18 + <Contact>
  19 + <PersonID>spase://SMWG/Person/Brian.J.Anderson</PersonID>
  20 + <Role>PrincipalInvestigator</Role>
  21 + </Contact>
  22 + <InformationURL>
  23 + <Name>AMPTE-CCE Magnetic Field Experiment Home Page</Name>
  24 + <URL>http://sd-www.jhuapl.edu/AMPTE/MAG/</URL>
  25 + <Description>MFE instrument information as well as spin-averaged-data</Description>
  26 + </InformationURL>
  27 + <InformationURL>
  28 + <Name>NSSDC Master Catalog</Name>
  29 + <URL>https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1984-088A-05</URL>
  30 + <Description>Information about the AMPTE-CCE magnetometer</Description>
  31 + </InformationURL>
  32 + </ResourceHeader>
  33 + <InstrumentType>Magnetometer</InstrumentType>
  34 + <InvestigationName>Magnetic Field Experiment</InvestigationName>
  35 + <ObservatoryID>spase://CNES/Observatory/CDPP-AMDA/CCE</ObservatoryID>
  36 + </Instrument>
  37 +</Spase>
... ...
Instrument/CDPP-AMDA/IRM/MAG.xml 0 → 100644
... ... @@ -0,0 +1,36 @@
  1 +<?xml version="1.0" encoding="UTF-8"?>
  2 +<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://amda.irap.omp.eu/public/schemas/spase-2_3_1.xsd">
  3 + <Version>2.2.6</Version>
  4 + <Instrument>
  5 + <ResourceID>spase://CNES/Instrument/CDPP-AMDA/IRM/MAG</ResourceID>
  6 + <ResourceHeader>
  7 + <ResourceName>AMPTE-IRM MAG</ResourceName>
  8 + <AlternateName>Triaxial Fluxgate magnetometer (MAG)</AlternateName>
  9 + <ReleaseDate>2019-05-05T12:34:56Z</ReleaseDate>
  10 + <Description>The instrument was a three-axis fluxgate magnetometer mounted on a 2 m boom.
  11 + It had two switchable ranges (±4 µT, and ±60 µT) with resolutions of 0.12 and 1.8 nT,
  12 + respectively and was read out at 32, 16, 8, or 4 vector samples per second,
  13 + depending on the T/M rate. Signals from each sensor were also fed into four band pass
  14 + filters with 5.5, 11, 22, and 44 Hz center frequencies and were read out up to two times per second.
  15 + </Description>
  16 + <Acknowledgement>User will acknowledge the AMPTE/IRM magnetometer team in any publication resulting from the use of these data.</Acknowledgement>
  17 + <Contact>
  18 + <PersonID>spase://SMWG/Person/Hermann.Luehr</PersonID>
  19 + <Role>PrincipalInvestigator</Role>
  20 + </Contact>
  21 + <InformationURL>
  22 + <Name>IRM magneotmeter information at University of New Hampshire</Name>
  23 + <URL>http://www-ssg.sr.unh.edu/index.html?tof/Missions/Ampte-irm/magnetic/magneticmain.html</URL>
  24 + <Description></Description>
  25 + </InformationURL>
  26 + <InformationURL>
  27 + <Name>NSSDC Master Catalog</Name>
  28 + <URL>https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1984-088B-02</URL>
  29 + <Description>Information about the AMPTE-IRM magnetometer</Description>
  30 + </InformationURL>
  31 + </ResourceHeader>
  32 + <InstrumentType>Magnetometer</InstrumentType>
  33 + <InvestigationName>Triaxial Fluxgate Magnetometer</InvestigationName>
  34 + <ObservatoryID>spase://CNES/Observatory/CDPP-AMDA/IRM</ObservatoryID>
  35 + </Instrument>
  36 +</Spase>
... ...
Instrument/CDPP-AMDA/UKS/MAG.xml 0 → 100644
... ... @@ -0,0 +1,34 @@
  1 +<?xml version="1.0" encoding="UTF-8"?>
  2 +<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://amda.irap.omp.eu/public/schemas/spase-2_3_1.xsd">
  3 + <Version>2.2.6</Version>
  4 + <Instrument>
  5 + <ResourceID>spase://CNES/Instrument/CDPP-AMDA/UKS/MAG</ResourceID>
  6 + <ResourceHeader>
  7 + <ResourceName>AMPTE-UKS MAG</ResourceName>
  8 + <AlternateName>Triaxial Fluxgate magnetometer (MAG)</AlternateName>
  9 + <ReleaseDate>2019-05-05T12:34:56Z</ReleaseDate>
  10 + <Description>
  11 + The instrument consisted of a three-axis orthogonal fluxgate magnetometer with ring core sensors.
  12 + It was a refurbished ISEE 1/2 flight spare. One of the two possible ranges, plus and minus 256 or 8192 nT, could be selected by ground command.
  13 + The accuracy of the instrument was +/- 1 nT per axis in the high range and +/- 0.03 nT in the low range.
  14 + </Description>
  15 + <Acknowledgement>User will acknowledge the AMPTE/UKS magnetometer team in any publication resulting from the use of these data.</Acknowledgement>
  16 + <Contact>
  17 + <PersonID>spase://SMWG/Person/David.J.Southwood</PersonID>
  18 + <Role>PrincipalInvestigator</Role>
  19 + </Contact>
  20 + <Contact>
  21 + <PersonID>spase://SMWG/Person/Malcolm.W.Dunlop</PersonID>
  22 + <Role>DataProducer</Role>
  23 + </Contact>
  24 + <InformationURL>
  25 + <Name>NSSDC Master Catalog</Name>
  26 + <URL>https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1984-088C-04</URL>
  27 + <Description>Information about the AMPTE-UKS magnetometer</Description>
  28 + </InformationURL>
  29 + </ResourceHeader>
  30 + <InstrumentType>Magnetometer</InstrumentType>
  31 + <InvestigationName>Triaxial Fluxgate Magnetometer</InvestigationName>
  32 + <ObservatoryID>spase://CNES/Observatory/CDPP-AMDA/UKS</ObservatoryID>
  33 + </Instrument>
  34 +</Spase>
... ...