Commit d8e1c617e22765bbeff0c3cc7f4230a852278787
1 parent
02db57b3
Exists in
master
and in
11 other branches
Added Descriptions of Magnetometers for AMPTE - CCE, IRM and UKS
Showing
3 changed files
with
107 additions
and
0 deletions
Show diff stats
... | ... | @@ -0,0 +1,37 @@ |
1 | +<?xml version="1.0" encoding="UTF-8"?> | |
2 | +<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://amda.irap.omp.eu/public/schemas/spase-2_3_1.xsd"> | |
3 | + <Version>2.2.6</Version> | |
4 | + <Instrument> | |
5 | + <ResourceID>spase://CNES/Instrument/CDPP-AMDA/CCE/MAG</ResourceID> | |
6 | + <ResourceHeader> | |
7 | + <ResourceName>AMPTE-CCE MAG</ResourceName> | |
8 | + <AlternateName>Magnetic Field Experiment (MFE)</AlternateName> | |
9 | + <ReleaseDate>2019-05-05T12:34:56Z</ReleaseDate> | |
10 | + <Description>The Magnetic Field Experiment (MFE) includes a fluxgate magnetometer sensor mounted on a 2.3 m boom. | |
11 | + The fluxgate sensor was sampled at a rate of 8 vector samples/s. It had seven automatically switchable ranges (from +/- 16 nT to +/- 65,536 nT) with resolution | |
12 | + commensurate with a 13-bit A/D converter, and was read out at 8.6 vector samples/s. The signals from two sensors | |
13 | + (one parallel to the spin axis and one orthogonal) were also fed into 5-50 Hz bandpass channels that were read out every 5 s. | |
14 | + The data span the entire AMPTE-CCE mission, from 1984 day 234, August 21, through 1989 day 009 with occasional data gaps. | |
15 | + A lengthy data gap occurred in 1986 from day 252, September 9 through day 286, October 12, during an extended eclipse period. | |
16 | + </Description> | |
17 | + <Acknowledgement>User will acknowledge the AMPTE/CCE magnetometer team in any publication resulting from the use of these data.</Acknowledgement> | |
18 | + <Contact> | |
19 | + <PersonID>spase://SMWG/Person/Brian.J.Anderson</PersonID> | |
20 | + <Role>PrincipalInvestigator</Role> | |
21 | + </Contact> | |
22 | + <InformationURL> | |
23 | + <Name>AMPTE-CCE Magnetic Field Experiment Home Page</Name> | |
24 | + <URL>http://sd-www.jhuapl.edu/AMPTE/MAG/</URL> | |
25 | + <Description>MFE instrument information as well as spin-averaged-data</Description> | |
26 | + </InformationURL> | |
27 | + <InformationURL> | |
28 | + <Name>NSSDC Master Catalog</Name> | |
29 | + <URL>https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1984-088A-05</URL> | |
30 | + <Description>Information about the AMPTE-CCE magnetometer</Description> | |
31 | + </InformationURL> | |
32 | + </ResourceHeader> | |
33 | + <InstrumentType>Magnetometer</InstrumentType> | |
34 | + <InvestigationName>Magnetic Field Experiment</InvestigationName> | |
35 | + <ObservatoryID>spase://CNES/Observatory/CDPP-AMDA/CCE</ObservatoryID> | |
36 | + </Instrument> | |
37 | +</Spase> | |
... | ... |
... | ... | @@ -0,0 +1,36 @@ |
1 | +<?xml version="1.0" encoding="UTF-8"?> | |
2 | +<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://amda.irap.omp.eu/public/schemas/spase-2_3_1.xsd"> | |
3 | + <Version>2.2.6</Version> | |
4 | + <Instrument> | |
5 | + <ResourceID>spase://CNES/Instrument/CDPP-AMDA/IRM/MAG</ResourceID> | |
6 | + <ResourceHeader> | |
7 | + <ResourceName>AMPTE-IRM MAG</ResourceName> | |
8 | + <AlternateName>Triaxial Fluxgate magnetometer (MAG)</AlternateName> | |
9 | + <ReleaseDate>2019-05-05T12:34:56Z</ReleaseDate> | |
10 | + <Description>The instrument was a three-axis fluxgate magnetometer mounted on a 2 m boom. | |
11 | + It had two switchable ranges (±4 µT, and ±60 µT) with resolutions of 0.12 and 1.8 nT, | |
12 | + respectively and was read out at 32, 16, 8, or 4 vector samples per second, | |
13 | + depending on the T/M rate. Signals from each sensor were also fed into four band pass | |
14 | + filters with 5.5, 11, 22, and 44 Hz center frequencies and were read out up to two times per second. | |
15 | + </Description> | |
16 | + <Acknowledgement>User will acknowledge the AMPTE/IRM magnetometer team in any publication resulting from the use of these data.</Acknowledgement> | |
17 | + <Contact> | |
18 | + <PersonID>spase://SMWG/Person/Hermann.Luehr</PersonID> | |
19 | + <Role>PrincipalInvestigator</Role> | |
20 | + </Contact> | |
21 | + <InformationURL> | |
22 | + <Name>IRM magneotmeter information at University of New Hampshire</Name> | |
23 | + <URL>http://www-ssg.sr.unh.edu/index.html?tof/Missions/Ampte-irm/magnetic/magneticmain.html</URL> | |
24 | + <Description></Description> | |
25 | + </InformationURL> | |
26 | + <InformationURL> | |
27 | + <Name>NSSDC Master Catalog</Name> | |
28 | + <URL>https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1984-088B-02</URL> | |
29 | + <Description>Information about the AMPTE-IRM magnetometer</Description> | |
30 | + </InformationURL> | |
31 | + </ResourceHeader> | |
32 | + <InstrumentType>Magnetometer</InstrumentType> | |
33 | + <InvestigationName>Triaxial Fluxgate Magnetometer</InvestigationName> | |
34 | + <ObservatoryID>spase://CNES/Observatory/CDPP-AMDA/IRM</ObservatoryID> | |
35 | + </Instrument> | |
36 | +</Spase> | |
... | ... |
... | ... | @@ -0,0 +1,34 @@ |
1 | +<?xml version="1.0" encoding="UTF-8"?> | |
2 | +<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://amda.irap.omp.eu/public/schemas/spase-2_3_1.xsd"> | |
3 | + <Version>2.2.6</Version> | |
4 | + <Instrument> | |
5 | + <ResourceID>spase://CNES/Instrument/CDPP-AMDA/UKS/MAG</ResourceID> | |
6 | + <ResourceHeader> | |
7 | + <ResourceName>AMPTE-UKS MAG</ResourceName> | |
8 | + <AlternateName>Triaxial Fluxgate magnetometer (MAG)</AlternateName> | |
9 | + <ReleaseDate>2019-05-05T12:34:56Z</ReleaseDate> | |
10 | + <Description> | |
11 | + The instrument consisted of a three-axis orthogonal fluxgate magnetometer with ring core sensors. | |
12 | + It was a refurbished ISEE 1/2 flight spare. One of the two possible ranges, plus and minus 256 or 8192 nT, could be selected by ground command. | |
13 | + The accuracy of the instrument was +/- 1 nT per axis in the high range and +/- 0.03 nT in the low range. | |
14 | + </Description> | |
15 | + <Acknowledgement>User will acknowledge the AMPTE/UKS magnetometer team in any publication resulting from the use of these data.</Acknowledgement> | |
16 | + <Contact> | |
17 | + <PersonID>spase://SMWG/Person/David.J.Southwood</PersonID> | |
18 | + <Role>PrincipalInvestigator</Role> | |
19 | + </Contact> | |
20 | + <Contact> | |
21 | + <PersonID>spase://SMWG/Person/Malcolm.W.Dunlop</PersonID> | |
22 | + <Role>DataProducer</Role> | |
23 | + </Contact> | |
24 | + <InformationURL> | |
25 | + <Name>NSSDC Master Catalog</Name> | |
26 | + <URL>https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1984-088C-04</URL> | |
27 | + <Description>Information about the AMPTE-UKS magnetometer</Description> | |
28 | + </InformationURL> | |
29 | + </ResourceHeader> | |
30 | + <InstrumentType>Magnetometer</InstrumentType> | |
31 | + <InvestigationName>Triaxial Fluxgate Magnetometer</InvestigationName> | |
32 | + <ObservatoryID>spase://CNES/Observatory/CDPP-AMDA/UKS</ObservatoryID> | |
33 | + </Instrument> | |
34 | +</Spase> | |
... | ... |