cass-lemms-pha1min.xml
4.49 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
<?xml version="1.0" encoding="UTF-8"?>
<Spase xmlns="http://www.spase-group.org/data/schema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.spase-group.org/data/schema http://cdpp.irap.omp.eu/AMDA-NG/public/schemas/spase-amda-1_2_0.xsd">
<Version>2.2.6</Version>
<NumericalData>
<ResourceID>spase://CDPP/NumericalData/AMDA/Cassini/MIMI-LEMMS/cass-lemms-pha1min</ResourceID>
<ResourceHeader>
<ResourceName>1min</ResourceName>
<AlternateName>One minute average particle intensity from PHA</AlternateName>
<ReleaseDate>2017-10-19T15:21:00</ReleaseDate>
<Description>One minute average particle intensity data for PHA (Pulse Height Analysis) ion and electron channels.
There are three types of channels included in these averages: the A channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).</Description>
<Contact>
<PersonID>spase://CDPP/Person/Jon.Vandegriff</PersonID>
<Role>DataProducer</Role>
</Contact>
<Association>
<AssociationID>cass-lemms-pha</AssociationID>
<AssociationType>PartOf</AssociationType>
<Note>flux from PHA data</Note>
</Association>
</ResourceHeader>
<AccessInformation>
<RepositoryID>spase://SMWG/Repository/CDPP/AMDA</RepositoryID>
<Availability>Online</Availability>
<AccessRights>Open</AccessRights>
<AccessURL>
<Name>AMDA</Name>
<URL>amda.cdpp.eu</URL>
</AccessURL>
<Format>NetCDF</Format>
</AccessInformation>
<ProviderName>PDS</ProviderName>
<ProviderResourceName>CO-S-MIMI-4-LEMMS-CALIB-V1.0/LPHAAVG0_1MIN</ProviderResourceName>
<InstrumentID>spase://CDPP/Instrument/AMDA/Cassini/MIMI-LEMMS</InstrumentID>
<MeasurementType>EnergeticParticles</MeasurementType>
<TemporalDescription>
<TimeSpan>
<StartDate>2004-01-01T00:00:30Z</StartDate>
<StopDate>2017-03-31T23:59:30Z</StopDate>
</TimeSpan>
<Cadence>PT60S</Cadence>
</TemporalDescription>
<ObservedRegion>Saturn</ObservedRegion>
<Caveats>The data is background subtracted, and thus occasionally there will be negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.
</Caveats>
<Parameter>
<Name>ions A</Name>
<ParameterKey>cass_lemms_pha1mina</ParameterKey>
<Description/>
<Ucd>phot.count;phys.atmol.ionStage</Ucd>
<Units>cm-2.sr-1.s-1.keV-1</Units>
<RenderingHints>
<DisplayType>Spectrogram</DisplayType>
</RenderingHints>
<Particle>
<ParticleType>Ion</ParticleType>
<ParticleQuantity>NumberFlux</ParticleQuantity>
</Particle>
</Parameter>
<Parameter>
<Name>electrons E</Name>
<ParameterKey>cass_lemms_pha1mine</ParameterKey>
<Description/>
<Ucd>phot.count;phys.electron</Ucd>
<Units>cm-2.sr-1.s-1.keV-1</Units>
<RenderingHints>
<DisplayType>Spectrogram</DisplayType>
</RenderingHints>
<Particle>
<ParticleType>Electron</ParticleType>
<ParticleQuantity>NumberFlux</ParticleQuantity>
</Particle>
</Parameter>
<Parameter>
<Name>electrons F1</Name>
<ParameterKey>cass_lemms_pha1minf1</ParameterKey>
<Description/>
<Ucd>phot.count;phys.electron</Ucd>
<Units>cm-2.sr-1.s-1.keV-1</Units>
<RenderingHints>
<DisplayType>Spectrogram</DisplayType>
</RenderingHints>
<Particle>
<ParticleType>Electron</ParticleType>
<ParticleQuantity>NumberFlux</ParticleQuantity>
</Particle>
</Parameter>
</NumericalData>
</Spase>