MAG.xml 1.87 KB
<?xml version="1.0" encoding="UTF-8"?>
<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://amda.irap.omp.eu/public/schemas/spase-2_3_1.xsd">
  <Version>2.3.1</Version>
  <Instrument>
    <ResourceID>spase://CNES/Instrument/CDPP-AMDA/UKS/MAG</ResourceID>
    <ResourceHeader>
      <ResourceName>FGM</ResourceName>
      <AlternateName>Triaxial Fluxgate Magnetometer</AlternateName>
      <ReleaseDate>2019-05-05T12:34:56Z</ReleaseDate>
      <Description>
        The instrument consisted of a three-axis orthogonal fluxgate magnetometer with ring core sensors. 
        It was a refurbished ISEE 1/2 flight spare. One of the two possible ranges, plus and minus 256 or 8192 nT, could be selected by ground command. 
        The accuracy of the instrument was +/- 1 nT per axis in the high range and +/- 0.03 nT in the low range.
      </Description>
      <Acknowledgement>User will acknowledge the AMPTE/UKS magnetometer team in any publication resulting from the use of these data.</Acknowledgement>
      <Contact>
        <PersonID>spase://SMWG/Person/David.J.Southwood</PersonID>
        <Role>PrincipalInvestigator</Role>
      </Contact>
      <Contact>
        <PersonID>spase://SMWG/Person/Malcolm.W.Dunlop</PersonID>
        <Role>DataProducer</Role>
      </Contact>
      <InformationURL>
        <Name>NSSDC Master Catalog</Name>
        <URL>https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1984-088C-04</URL>
        <Description>Information about the AMPTE-UKS magnetometer</Description>
      </InformationURL>
    </ResourceHeader>
    <InstrumentType>Magnetometer</InstrumentType>
    <InvestigationName>Triaxial Fluxgate Magnetometer</InvestigationName>
    <ObservatoryID>spase://CNES/Observatory/CDPP-AMDA/AMPTE/UKS</ObservatoryID>
  </Instrument>