<?xml version="1.0" encoding="UTF-8"?>
<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://amda.irap.omp.eu/public/schemas/spase-2_3_1.xsd">
  <Version>2.2.6</Version>
  <Instrument>
    <ResourceID>spase://CNES/Instrument/CDPP-AMDA/IRM/MAG</ResourceID>
    <ResourceHeader>
      <ResourceName>MAG</ResourceName>
      <AlternateName>Triaxial Fluxgate magnetometer (MAG)</AlternateName>
      <ReleaseDate>2019-05-05T12:34:56Z</ReleaseDate>
      <Description>The instrument was a three-axis fluxgate magnetometer mounted on a 2 m boom. 
        It had two switchable ranges (±4 µT, and ±60 µT) with resolutions of 0.12 and 1.8 nT, 
        respectively and was read out at 32, 16, 8, or 4 vector samples per second, 
        depending on the T/M rate. Signals from each sensor were also fed into four band pass 
        filters with 5.5, 11, 22, and 44 Hz center frequencies and were read out up to two times per second. 
        The IRM's spin is constant over the period of the measurements at 4.053 s
      </Description>
      <Acknowledgement>User will acknowledge the AMPTE/IRM magnetometer team in any publication resulting from the use of these data.</Acknowledgement>
      <Contact>
        <PersonID>spase://SMWG/Person/Hermann.Luehr</PersonID>
        <Role>PrincipalInvestigator</Role>
      </Contact>
      <InformationURL>
        <Name>IRM magneotmeter information at University of New Hampshire</Name>
        <URL>http://www-ssg.sr.unh.edu/index.html?tof/Missions/Ampte-irm/magnetic/magneticmain.html</URL>
        <Description></Description>
      </InformationURL>
      <InformationURL>
        <Name>NSSDC Master Catalog</Name>
        <URL>https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1984-088B-02</URL>
        <Description>Information about the AMPTE-IRM magnetometer</Description>
      </InformationURL>
    </ResourceHeader>
    <InstrumentType>Magnetometer</InstrumentType>
    <InvestigationName>Triaxial Fluxgate Magnetometer</InvestigationName>
    <ObservatoryID>spase://CNES/Observatory/CDPP-AMDA/AMPTE/IRM</ObservatoryID>
  </Instrument>