so-step-rates.xml
7.71 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
<?xml version="1.0" encoding="UTF-8"?>
<Spase xmlns="http://www.spase-group.org/data/schema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2_3_0.xsd">
<Version>2.3.0</Version>
<NumericalData>
<ResourceID>spase://CNES/NumericalData/CDPP-AMDA/Solar_Orbiter/EPD/so-step-rates</ResourceID>
<ResourceHeader>
<ResourceName>flux</ResourceName>
<AlternateName>Flux averaged over sectors</AlternateName>
<ReleaseDate>2019-11-12T10:48:29Z</ReleaseDate>
<Description>Solar Orbiter, Level 2 Data, Energetic Particle Detector, SupraThermal Electrons and Protons, Rates.
STEP is designed to measure electrons and ions in the suprathermal energy range (280 keV). To
allow for the separation of electrons and ions, STEP has 2 different channels, each equipped with its
own solid state detectors for detecting particles:
* Magnet channel. Uses a permanent magnet to deflect electrons, measuring only ions (mostly protons).
* Integral channel. Measures all incoming particles.
The electron flux is recovered by subtracting the magnet channel measurements from the integral
channel ones. Each channel is divided in 15 sectors, disposed in 3 rows of 5 pixels, providing
directional information of the incoming particles within the field of view. An additional pixel, not directly
exposed to the incoming flux, measures the cosmic ray background.</Description>
<Acknowledgement>See http://espada.uah.es/epd/EPD_data.php</Acknowledgement>
<Contact>
<PersonID>spase://CDPP/Person/J.Rodrigues-Pacheco</PersonID>
<Role>PrincipalInvestigator</Role>
</Contact>
<InformationURL>
<Name>SolO Archive Support Data</Name>
<URL>https://issues.cosmos.esa.int/solarorbiterwiki/display/SOSP/Archive+Support+Data</URL>
<Description></Description>
</InformationURL>
<Association>
<AssociationID>solo-epd-step</AssociationID>
<AssociationType>PartOf</AssociationType>
<Note>L2 : rates</Note>
</Association>
</ResourceHeader>
<AccessInformation>
<RepositoryID>spase://SMWG/Repository/CNES/CDPP-AMDA</RepositoryID>
<Availability>Online</Availability>
<AccessRights>Open</AccessRights>
<AccessURL>
<Name>AMDA at CDPP</Name>
<URL>http://amda.cdpp.eu</URL>
</AccessURL>
<Format>Text</Format>
<Acknowledgement>
AMDA is a science analysis system provided by the Centre de Donnees de la
Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and
Universite Paul Sabatier, Toulouse
</Acknowledgement>
</AccessInformation>
<ProviderName>http://soar.esac.esa.int/soar</ProviderName>
<ProviderResourceName>EPD-STEP-RATES</ProviderResourceName>
<ProviderAcknowlegment></ProviderAcknowlegment>
<InstrumentID>spase://CNES/Instrument/CDPP-AMDA/Solar_Orbiter/EPD-STEP</InstrumentID>
<MeasurementType>EnergeticParticles</MeasurementType>
<TemporalDescription>
<TimeSpan>
<StartDate>2018-09-02T00:00:12Z</StartDate>
<StopDate>2025-08-12T23:59:55Z</StopDate>
</TimeSpan>
<CadenceMin>PT10S</CadenceMin>
<CadenceMax>PT60S</CadenceMax>
</TemporalDescription>
<ObservedRegion>Heliosphere.Inner</ObservedRegion>
<ObservedRegion>Sun.Corona</ObservedRegion>
<Parameter>
<Name>ion flux</Name>
<ParameterKey>solo_step_mflux</ParameterKey>
<Description>Magnet channel. Uses a permanet magnet to deflect electrons. Measuring only ions (mostly protons)</Description>
<Ucd/>
<Units>1/(s cm^2 sr MeV)</Units>
<UnitsConversion/>
<RenderingHints>
<DisplayType>Spectrogram</DisplayType>
</RenderingHints>
<Structure>
<Size>48</Size>
</Structure>
</Parameter>
<Parameter>
<Name>ion flux unc</Name>
<ParameterKey>solo_step_munc</ParameterKey>
<Description>Uncertainty in sector averaged magnet channel flux</Description>
<Ucd/>
<Units>1/(s cm^2 sr MeV)</Units>
<UnitsConversion/>
<RenderingHints>
<DisplayType>Spectrogram</DisplayType>
</RenderingHints>
<Structure>
<Size>48</Size>
</Structure>
</Parameter>
<Parameter>
<Name>ion cntrate</Name>
<ParameterKey>solo_step_mrate</ParameterKey>
<Description>Sector averaged magnet channel count rate</Description>
<Ucd/>
<Units>cnts/s</Units>
<UnitsConversion/>
<RenderingHints>
<DisplayType>Spectrogram</DisplayType>
</RenderingHints>
<Structure>
<Size>48</Size>
</Structure>
</Parameter>
<Parameter>
<Name>el flux</Name>
<ParameterKey>solo_step_eflux</ParameterKey>
<Description>The electron flux is recovered by subtracting the magnet channel measurements from the integral channel ones</Description>
<Ucd/>
<Units>1/(s cm^2 sr MeV)</Units>
<UnitsConversion/>
<RenderingHints>
<DisplayType>Spectrogram</DisplayType>
</RenderingHints>
<Structure>
<Size>48</Size>
</Structure>
</Parameter>
<Parameter>
<Name>total flux</Name>
<ParameterKey>solo_step_iflux</ParameterKey>
<Description>Integral channel. Measures all incoming particles</Description>
<Ucd/>
<Units>1/(s cm^2 sr MeV)</Units>
<UnitsConversion/>
<RenderingHints>
<DisplayType>Spectrogram</DisplayType>
</RenderingHints>
<Structure>
<Size>48</Size>
</Structure>
</Parameter>
<Parameter>
<Name>total flux unc</Name>
<ParameterKey>solo_step_iunc</ParameterKey>
<Description>Uncertainty in sector averaged integral channel flux</Description>
<Ucd/>
<Units>1/(s cm^2 sr MeV)</Units>
<UnitsConversion/>
<RenderingHints>
<DisplayType>Spectrogram</DisplayType>
</RenderingHints>
<Structure>
<Size>48</Size>
</Structure>
</Parameter>
<Parameter>
<Name>total cntrate</Name>
<ParameterKey>solo_step_irate</ParameterKey>
<Description>Sector averaged integral channel count rate</Description>
<Ucd/>
<Units>cnts/s</Units>
<UnitsConversion/>
<RenderingHints>
<DisplayType>Spectrogram</DisplayType>
</RenderingHints>
<Structure>
<Size>48</Size>
</Structure>
</Parameter>
<Parameter>
<Name>quality flag</Name>
<ParameterKey>solo_step_qf</ParameterKey>
<Description>0: Bad, 1: Known problems, 2: Survey data, 3: Good, 4: Excellent</Description>
<Ucd/>
<Units/>
<UnitsConversion/>
<RenderingHints>
<DisplayType>TimeSeries</DisplayType>
</RenderingHints>
</Parameter>
</NumericalData>
</Spase>