Blame view

Instrument/CDPP-AMDA/IRM/MAG.xml 2.14 KB
d8e1c617   Quentin Brzustowski   Added Description...
1
<?xml version="1.0" encoding="UTF-8"?>
4b907fdc   Benjamin Renard   cleanup_registry_...
2
3
<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2.4.1.xsd">
  <Version>2.4.1</Version>
d8e1c617   Quentin Brzustowski   Added Description...
4
5
6
  <Instrument>
    <ResourceID>spase://CNES/Instrument/CDPP-AMDA/IRM/MAG</ResourceID>
    <ResourceHeader>
49417d15   Quentin Brzustowski   Changed names of ...
7
      <ResourceName>MAG</ResourceName>
d8e1c617   Quentin Brzustowski   Added Description...
8
9
10
11
12
13
14
      <AlternateName>Triaxial Fluxgate magnetometer (MAG)</AlternateName>
      <ReleaseDate>2019-05-05T12:34:56Z</ReleaseDate>
      <Description>The instrument was a three-axis fluxgate magnetometer mounted on a 2 m boom. 
        It had two switchable ranges (±4 µT, and ±60 µT) with resolutions of 0.12 and 1.8 nT, 
        respectively and was read out at 32, 16, 8, or 4 vector samples per second, 
        depending on the T/M rate. Signals from each sensor were also fed into four band pass 
        filters with 5.5, 11, 22, and 44 Hz center frequencies and were read out up to two times per second. 
c7095bfb   Quentin Brzustowski   corrections on AM...
15
        The IRM's spin is constant over the period of the measurements at 4.053 s
d8e1c617   Quentin Brzustowski   Added Description...
16
17
18
19
20
21
22
23
24
      </Description>
      <Acknowledgement>User will acknowledge the AMPTE/IRM magnetometer team in any publication resulting from the use of these data.</Acknowledgement>
      <Contact>
        <PersonID>spase://SMWG/Person/Hermann.Luehr</PersonID>
        <Role>PrincipalInvestigator</Role>
      </Contact>
      <InformationURL>
        <Name>IRM magneotmeter information at University of New Hampshire</Name>
        <URL>http://www-ssg.sr.unh.edu/index.html?tof/Missions/Ampte-irm/magnetic/magneticmain.html</URL>
7ad064f4   Benjamin Renard   Cleanup master/am...
25
        </InformationURL>
d8e1c617   Quentin Brzustowski   Added Description...
26
27
28
29
30
31
32
33
      <InformationURL>
        <Name>NSSDC Master Catalog</Name>
        <URL>https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1984-088B-02</URL>
        <Description>Information about the AMPTE-IRM magnetometer</Description>
      </InformationURL>
    </ResourceHeader>
    <InstrumentType>Magnetometer</InstrumentType>
    <InvestigationName>Triaxial Fluxgate Magnetometer</InvestigationName>
499814ec   Quentin Brzustowski   corrected Observa...
34
    <ObservatoryID>spase://CNES/Observatory/CDPP-AMDA/AMPTE/IRM</ObservatoryID>
d8e1c617   Quentin Brzustowski   Added Description...
35
36
  </Instrument>
</Spase>