2.4.1
spase://CNES/NumericalData/CDPP-AMDA/ACE/EPAM/ace-epam-de
DE
ACE Electron Proton Alpha Monitor (EPAM) 5-min Level 2 Data
2024-09-23T19:07:50Z
ACE EPAM DE (Deflected Electrons) data. Taken from ACE EPAM Electron Proton Alpha Monitor (EPAM) Level 2 intensities at 5-min time resolution. Calibrated science quality data. The data are accessible via ftp in HDF and CDF from the ACE Science Center and CDAWeb, respectively, and in ASCII format from the value-added interfaces at those sites. The "parameter keys" given below are as used by CDAWeb.
Please acknowledge the ACE/EPAM instrument team and the ACE Science Center
spase://SMWG/Person/Dennis.Haggerty
TechnicalContact
spase://SMWG/Person/Robert.E.Gold
CoInvestigator
ACE Electron Proton Alpha Monitor (EPAM) Level 2 data Home Page
http://www.srl.caltech.edu/ACE/ASC/level2/epam_l2desc.html
A web site hosting instrument information, data release notes, as well as web utilities for plotting and downloading data
Rules of use, and caveats
http://www.srl.caltech.edu/ACE/ASC/level2/policy_lvl2.html
ACE level 2 data rules of use, and caveats
ace-epam-h1
spase://SMWG/Repository/CDPP/AMDA
Online
Open
CDPP/AMDA HAPI Server
https://amda.irap.omp.eu/service/hapi
ace-epam-de
Web Service to this product using the HAPI interface.
CSV
Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.
spase://SMWG/Repository/CDPP/AMDA
Online
Open
CDPP/AMDA Web application
https://amda.cdpp.eu
Access to Data via CDPP/AMDA Web application.
CSV
VOTable
CDF
PNG
Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.
CDAWeb
AC_H1_EPM
Level 2
5
spase://CNES/Instrument/CDPP-AMDA/ACE/EPAM
EnergeticParticles
1997-08-30T17:01:00Z
2024-08-30T23:56:00Z
PT5M
The quality of ACE level 2 data is such that it is suitable for serious scientific study. However, to avoid confusion and misunderstanding, it is recommended that users consult with the appropriate ACE team members before publishing work derived from the data The ACE team has worked hard to ensure that the level 2 data are free from errors, but the team cannot accept responsibility for erroneous data, or for misunderstandings about how the data may be used. This is especially true if the appropriate ACE team members are not consulted before publication. At the very least, preprints should be forwarded to the ACE team before publication.
e- flux
ace_epam_de_e
DE MeV Electron Flux
1/(cm^2 s sr MeV)
4
0.038 - 0.053 MeV
1
ace_epam_de_e(0)
0.053 - 0.103 MeV
2
ace_epam_de_e(1)
0.103 - 0.175 MeV
3
ace_epam_de_e(2)
0.175 - 0.315 MeV
4
ace_epam_de_e(3)
Electron
Differential
NumberFlux
uncertainty
ace_epam_de_unce
Fractional uncertainty (statistical) in the DE flux
Ratio
4
0.038 - 0.053 MeV
1
ace_epam_de_unce(0)
0.053 - 0.103 MeV
2
ace_epam_de_unce(1)
0.103 - 0.175 MeV
3
ace_epam_de_unce(2)
0.175 - 0.315 MeV
4
ace_epam_de_unce(3)
Electron
Uncertainty
NumberFlux