2.4.1 spase://CNES/NumericalData/CDPP-AMDA/Galileo/EPD/gll-epd-ert electron channels Energetic electrons : omnidirectional 2019-03-13T08:45:40Z Energetic electron count rates and fluxes measured by the EPD instrument onboard Galileo in the Real Time acquisition mode. In this mode, the count rates are accumulated during 10 to 12 minutes. This accumulation period is long enough so that the EPD telescopes have pointed towards all the direction of the sky. The count rates and fluxes measured with the Real Time acquisition mode are therefore omnidirectionnal observations. Data are extracted from the text file named 'galileo_epd_calibrated_low_res_v18.txt' produced and provided by JHU/APL and publicly available at http://sd-www.jhuapl.edu/Galileo_EPD/latest_calibrated_data/. It is highly recommended to read the 'readme_v19.docx' document also available at the previous link before using this dataset. It is also recommended to contact Peter Kollmann (JHU/APL), as some measurement channels are highly contaminated or saturated. All unreliable measurements are set to NaN. Energies observed by each measurement channel are discussed in detail in Kollmann et al. [2018, JGR]. spase://SMWG/Person/Donald.J.Williams PrincipalInvestigator spase://CNES/Person/CDPP-AMDA/Peter.Kollmann DataProducer spase://CNES/Person/CDPP-AMDA/Quentin.Nenon DataProducer spase://CNES/Person/CDPP-AMDA/Christopher.Paranicas CoInvestigator spase://CNES/Person/CDPP-AMDA/Norbert.Krupp CoInvestigator gll-epd-realtime PartOf realtime mode spase://SMWG/Repository/CDPP/AMDA Online Open CDPP/AMDA HAPI Server https://amda.irap.omp.eu/service/hapi gll-epd-ert Web Service to this product using the HAPI interface. CSV Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers. spase://SMWG/Repository/CDPP/AMDA Online Open CDPP/AMDA Web application https://amda.cdpp.eu Access to Data via CDPP/AMDA Web application. CSV VOTable CDF PNG Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers. JHU/APL http://sd-www.jhuapl.edu/Galileo_EPD/latest_calibrated_data/galileo_epd_calibrated_low_res_v18.txt spase://CNES/Instrument/CDPP-AMDA/Galileo/EPD EnergeticParticles 1996-05-27T00:14:24Z 2003-09-21T18:15:57Z PT600S PT720S Jupiter Electron channels : * B1 : ≥ 36.2 MeV * DC0 : ≥ 14 MeV * DC1 : ≥ 30 MeV * DC2 : ≥ 1.8 MeV * DC3 : ≥ 10.8 MeV * E[0-3] : 15 - 93 keV * F[0-3] : 93 - 884 keV L-shell gll_epd_l_e TimeSeries Other e- : E[0-3] : cnts gll_epd_ecounts s**-1 Spectrogram 4 Electron CountRate e- : E[0-3] : flux gll_epd_eflux cm**-2.s**-1.sr**-1.keV**-1 Spectrogram 4 Electron NumberFlux e- : F[0-3] : cnts gll_epd_fcounts s**-1 Spectrogram 4 Electron CountRate e- : F[0-3] : flux gll_epd_fflux cm**-2.s**-1.sr**-1.keV**-1 Spectrogram 4 Electron NumberFlux e- : B1 : cnts gll_epd_bcnts_e s**-1 TimeSeries Electron CountRate e- : DC[0-3] : cnts gll_epd_dccounts s**-1 TimeSeries 4 DC0 : > 14 MeV 1 gll_epd_dccounts(0) DC1 : > 30 MeV 2 gll_epd_dccounts(1) DC2 : > 1.8 MeV 3 gll_epd_dccounts(2) DC3 : > 10.8 MeV 3 gll_epd_dccounts(3) Electron CountRate