2.2.6
spase://CDPP/NumericalData/AMDA/Cluster/Cluster1/CIS-HIA/clust1-hia-pad
pitch angle distribution
2015-10-19T10:51:45Z
This instrument (CIS: Cluster Ion Spectrometry) is capable of obtaining full 3D ion distributions with high time resolution (in one spacecraft spin) and mass-per-charge resolution. The experiment consists of two different instruments, a Hot Ion Analyzer (HIA) and a time-of-flight Ion Composition and Distribution Function analyzer (CODIF). Extensive on-board processing is done, within its dual-processor Data Processing System (DPS). CODIF determines the distributions of the major ion species with energies from spacecraft potential to 40 KeV/charge with an angular resolution of 22.5 x 10.25 degrees and with two different sensitivities. The CODIF instrument uses electrostatic deflection to select by energy per charge, with subsequent time-of-flight analysis. The sensor primarily covers the energy range 0.02-40 KeV/charge, but with additional pre-acceleration for energies below 25 eV/charge, the range is extended to energies as low as the spacecraft potential. The HIA does not measure mass, but extends the dynamic range to the highest ion fluxes, and has angular resolution capability of 5.6 x 5.6 degrees for ion-beam and solar-wind measurements. The HIA is a symmetric quadrispherical analyzer of top-hat geometry, and uses microchannel-plate electron multipliers and position encoding by discrete anodes. A 2D distribution is obtained once per 62.5 ms, and a full 3D distribution of ions in the energy range ~5 eV/charge to 32 KeV/charge is obtained every 4 s. For more details of the Cluster mission, the spacecraft, and its instruments, see the report Cluster: mission, payload and supporting activities, March 1993, ESA SP-1159, and the included article The Cluster Ion Spectrometry Experiment, by H. Reme et al., from which this information was obtained.
NASA, Prof. Henri Reme, European Space Agency
spase://SMWG/Person/Henri.Reme
PrincipalInvestigator
spase://SMWG/Person/Elena.Budnik
TechnicalContact
NSSDC Master Catalog listing for Cluster II Rumba Cluster Ion Spectrometry (CIS)
http://nssdc.gsfc.nasa.gov/nmc/experimentDisplay.do?id=2000-045A-02
This site provides information concerning the Cluster II Rumba Cluster Ion Spectrometry Instrument.
spase://SMWG/Repository/CDPP/AMDA
Online
Open
AMDA at CDPP
http://amda.cdpp.eu
NetCDF
NASA, Prof. Henri Reme
IRAP
Calibrated
Cluster II Rumba Prime Parameter Cluster Ion Spectrometry (CIS) Data
Calibrated
1
spase://CDPP/Instrument/AMDA/Cluster-Rumba/CIS-HIA
ThermalPlasma
2001-01-31T01:02:11Z
2011-12-31T14:14:55Z
PT4S
Earth.Magnetosheath
Earth.Magnetosphere
Earth.Magnetosphere.Magnetotail
Earth.Magnetosphere.Main
Earth.Magnetosphere.Polar
Earth.Magnetosphere.RadiationBelt
Earth.NearSurface.AuroralRegion
Earth.NearSurface.Ionosphere
Earth.NearSurface.Plasmasphere
Earth.NearSurface.PolarCap
Heliosphere.NearEarth
4 second
magnetosphere
auroral region
polar cap
cusp
bow shock
solar wind
magnetosheath
Cluster
magnetotail
lobe
Pitch angle distribution
c1_hia_pad
pos.posAng
PT4S
cnts/(cm2 s sr Kev)
Spectrogram
Other
Pitch angle distribution : sum over all energies
c1_hia_pad_angle
pos.posAng
PT4S
cnts/(cm2 s sr Kev)
Spectrogram
Other
Energy distribution : sum over all pitch angles
c1_hia_pad_energy
pos.posAng
PT4S
cnts/(cm2 s sr Kev)
Spectrogram
Other