2.4.1
spase://CNES/NumericalData/CDPP-AMDA/Helios2/E1/helios2-e1-all
corefit : protons
Helios corefit data product
2018-11-06T18:14:12Z
Corefit data set contains
estimates of number density, velocity, and temperatures of the proton core population in the
solar wind created from systematic fitting of all the original Helios 3D distribution functions.
Please acknowledge Helios E1 team and David Stansby in any publication
spase://CNES/Person/CDPP-AMDA/David.Stansby
DataProducer
spase://SMWG/Repository/CDPP/AMDA
Online
Open
CDPP/AMDA HAPI Server
https://amda.irap.omp.eu/service/hapi
helios2-e1-all
Web Service to this product using the HAPI interface.
CSV
Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.
spase://SMWG/Repository/CDPP/AMDA
Online
Open
CDPP/AMDA Web application
https://amda.cdpp.eu
Access to Data via CDPP/AMDA Web application.
CSV
VOTable
CDF
PNG
Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.
Helios Data Archive
Helios corefit data product
spase://CNES/Instrument/CDPP-AMDA/Helios2/E1
ThermalPlasma
1976-01-17T01:42:11Z
1980-03-08T17:46:32Z
PT40S
PT300S
Heliosphere
Status (fitting status flag) takes the following values:
* 1: successful fit;
* 2: successful fit, magnetic field varies too much for reliable number densities and temperatures;
* 3: successful fit, no magnetic field data available;
* 4: failed fit
Ion instrument flag takes the following values:
* 1: I1a ion instrument data;
* 2: I3 ion instrument data
status
helios2_e1_flag
-1
DataQuality
ion_instr
helios2_e1_instr
-1
InstrumentMode
density
helios2_e1_np
cm^-3
Proton
NumberDensity
t_para
helios2_e1_t_para
eV
Proton
Temperature
t_perp
helios2_e1_t_perp
eV
Proton
Temperature
v_thermal_para
helios2_e1_vth_para
km/s
Proton
Velocity
v_thermal_perp
helios2_e1_vth_perp
km/s
Proton
Velocity
v_rtn
helios2_e1_vp
km/s
3
vr
1
helios2_e1_vp(0)
vt
2
helios2_e1_vp(1)
vn
3
helios2_e1_vp(2)
Proton
Average
FlowSpeed