Blame view

NumericalData/CDPP-AMDA/MAVEN/SWIA/mav-swia-kp.xml 8.52 KB
dbc930ab   Elena.Budnik   redmine #7309
1
<?xml version="1.0" encoding="UTF-8"?>
7e407638   Elena.Budnik   schema locally
2
<Spase xmlns="http://www.spase-group.org/data/schema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.spase-group.org/data/schema http://amda.irap.omp.eu/public/schemas/spase-2_3_1.xsd">
dbc930ab   Elena.Budnik   redmine #7309
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
   <Version>2.3.1</Version>
   <NumericalData>
      <ResourceID>spase://CNES/NumericalData/CDPP-AMDA/MAVEN/SWIA/mav-swia-kp</ResourceID>
      <ResourceHeader>
         <ResourceName>ions : key parameters</ResourceName>
         <AlternateName>SWIA : ions considered as protons : key parameters</AlternateName>
         <ReleaseDate>2017-03-12T10:48:29Z</ReleaseDate>
         <Description>Data follow a 4-second cadence when MAVEN is at an altitude of less than 500 km, otherwise the time cadence is 8 seconds.     
          The in situ key parameters contain 235 parameters selected by the instrument leads and other MAVEN scientists. These data consist of values derived from L2 data provided by the in situ instruments.</Description>
         <Acknowledgement> Principal Investigator : Jasper Halekas, Univ. Iowa, Iowa City</Acknowledgement>
         <Contact>        
            <PersonID>spase://CNES/Person/Jasper.S.Halekas</PersonID>
            <Role>PrincipalInvestigator</Role>
         </Contact>
         <Contact>        
            <PersonID>spase://CNES/Person/P.Dunn</PersonID>
            <Role>DataProducer</Role>
         </Contact>
         <InformationURL>
            <Name>SWIA web page, Summary sheet </Name>
            <URL>http://lasp.colorado.edu/home/maven/science/instrument-package/swia/</URL>
           <Description>             
           </Description>
         </InformationURL>       
      </ResourceHeader>
      <AccessInformation>
eed3b876   Elena.Budnik   RepositoryId change
29
         <RepositoryID>spase://SMWG/Repository/CNES/CDPP-AMDA</RepositoryID>
dbc930ab   Elena.Budnik   redmine #7309
30
31
32
33
34
35
36
37
38
39
40
41
42
43
         <Availability>Online</Availability>
         <AccessRights>Open</AccessRights>
         <AccessURL>
            <Name>AMDA at CDPP</Name>
            <URL>http://amda.cdpp.eu</URL>
         </AccessURL>
         <Format>Text.ASCII</Format>
         <Acknowledgement> AMDA is a science analysis system provided by the Centre de Donnees de la 
            Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and 
            Universite Paul Sabatier, Toulouse            
         </Acknowledgement>
      </AccessInformation>
      <ProviderName>PDS</ProviderName> 
      <ProviderResourceName>/maven-insitu-calibrated</ProviderResourceName>
d1fe7122   Elena.Budnik   redmine 7309 cont...
44
      <InstrumentID>spase://CNES/Instrument/CDPP-AMDA/MAVEN/SWIA</InstrumentID>
dbc930ab   Elena.Budnik   redmine #7309
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
      <MeasurementType>ThermalPlasma</MeasurementType>
      <TemporalDescription>
         <TimeSpan>
             <StartDate>2014-10-06T00:00:00Z</StartDate>
             <StopDate>2018-05-14T23:59:52Z</StopDate>
         </TimeSpan>
       <CadenceMin>PT4S</CadenceMin>
       <Cadence_Max>PT8S</Cadence_Max>  
      </TemporalDescription>
      <ObservedRegion>Mars</ObservedRegion>
      <Caveats>Quality flag (0 = bad, 1 = good) indicats whether the distribution is well-measured and decommutation parameters are definite.                       
        All SWIA Key Parameters are derived from onboard-computed moments. These moments are computed under the assumption that all ions are protons, and that the entire distribution is within the field of view and the energy range of the instrument.
The quality flag in the KP files attempts to identify and flag those cases where a significant portion of the distribution is outside of SWIA's field of view and/or outside of the energy range of the instrument, but the computation of the quality flag is not infallible and there may still be cases where part of the distribution is missing. Meanwhile, there is no quality flag or correction for multi-ion issues.
Thus, SWIA key parameter data taken inside the induced magnetospheric boundary should typically not be used for quantitative purposes. Even in the solar wind, which is ~94-97% protons, there are some values which cannot be used quantitatively, since the moments are computed over a distribution which includes not only the protons, but also ~3-6% alpha particles with twice the energy per charge. This has only a few percent effect on the density and velocity moments, so these values can safely be relied on, but even a small alpha population leads to an artificially large temperature moment (particularly the component aligned with the flow, which is often 2x or more higher than the true value).
Thus, the SWIA temperature moments cannot typically be used for quantitative purposes [for qualitative purposes they may be okay in the solar wind and magnetosheath].
Those wishing to look quantitatively at solar wind temperature should use the SWIA Level 2 3-d Fine data and use appropriate routines to separately compute proton and alpha temperature.
      </Caveats>    
      <Parameter>
         <Name>density</Name>
         <ParameterKey>mav_swiakp_n</ParameterKey>
         <Description>Total ion density from SWIA onboard moment calculation, assuming 100% protons</Description>
         <Ucd>phys.density;phys.atmol.ionStage</Ucd>
         <Units>cm-3</Units>
         <UnitsConversion/>
         <Particle>
            <ParticleType>Ion</ParticleType>
            <ParticleQuantity>NumberDensity</ParticleQuantity>
         </Particle>
      </Parameter> 
      <Parameter>
         <Name>moments quality</Name>
         <ParameterKey>mav_swiakp_qual</ParameterKey>
         <Description>Quality flag (0 = bad, 1 = good) indicating whether the distribution is well-measured and decommutation parameters are definite</Description>
         <Ucd/>
         <Units/>
         <UnitsConversion/>
         <Support>
            <SupportQuantity>Other</SupportQuantity>
         </Support>
      </Parameter>
      <Parameter>
         <Name>v_mso</Name>
         <ParameterKey>mav_swiakp_vmso</ParameterKey>
         <Description>Bulk ion flow velocity from SWIA onboard moment calculation, assuming 100% protons</Description>
         <Ucd>phys.veloc;phys.atmol.ionStage</Ucd>
         <Units>km/s</Units>
         <UnitsConversion/>
         <Structure>
            <Size>3</Size>
            <Element>
               <Name>vx</Name>
               <Index>1</Index>
               <ParameterKey>mav_swiakp_vmso(0)</ParameterKey>
               <ValidMin/>
               <ValidMax/>
               <FillValue/>
            </Element>
            <Element>
               <Name>vy</Name>
               <Index>2</Index>
               <ParameterKey>mav_swiakp_vmso(1)</ParameterKey>
               <ValidMin/>
               <ValidMax/>
               <FillValue/>
            </Element>
            <Element><Name>vz</Name>
               <Index>3</Index>
               <ParameterKey>mav_swiakp_vmso(2)</ParameterKey>
               <ValidMin/>
               <ValidMax/>
               <FillValue/>
            </Element>
         </Structure>
         <Particle>
            <ParticleType>Ion</ParticleType>
            <ParticleQuantity>Velocity</ParticleQuantity>
         </Particle>
      </Parameter>
        <Parameter>
         <Name>|v|</Name>
         <ParameterKey>mav_swiakp_vtot</ParameterKey>
         <Description>Bulk ion flow velocity magnitude from SWIA onboard moment calculation, assuming 100% protons</Description>
         <Ucd>phys.veloc;phys.atmol.ionStage</Ucd>
         <Units>km/s</Units>
         <UnitsConversion/>         
         <Particle>
            <ParticleType>Ion</ParticleType>
            <ParticleQuantity>Velocity</ParticleQuantity>
         </Particle>
      </Parameter>
      <Parameter>
         <Name>temperature</Name>
         <ParameterKey>mav_swiakp_t</ParameterKey>
         <Description> Scalar ion temperature from SWIA onboard moment calculation, assuming 100% protons</Description>
         <Ucd>phys.temperature;phys.atmol.Ionstage</Ucd>
         <Units>eV</Units>
        <UnitsConversion/>              
         <Particle>
            <ParticleType>Ion</ParticleType>
            <ParticleQuantity>Temperature</ParticleQuantity>
         </Particle>          
      </Parameter>       
      <Parameter>
         <Name>dynamic pressure</Name>
         <ParameterKey>mav_swiakp_pdyn</ParameterKey>
         <Description>Ion dynamic pressure computed on the SWIA ground from density and velocity moments, assuming 100% protons</Description>
         <Ucd>phys.temperature;phys.atmol.Ionstage</Ucd>
         <Units>nPa</Units>
        <UnitsConversion/>              
         <Particle>
            <ParticleType>Ion</ParticleType>
            <ParticleQuantity>Pressure</ParticleQuantity>
         </Particle>          
      </Parameter>
   </NumericalData>
</Spase>