Blame view

NumericalData/AMDA/Rosetta/LAP/ros-lap-efl.xml 6.01 KB
303f2ca9   Elena.Budnik   Rosetta LAP EFL
1
2
3
4
5
6
7
8
9
<?xml version="1.0" encoding="UTF-8"?>
<Spase xmlns="http://www.spase-group.org/data/schema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.spase-group.org/data/schema http://cdpp.irap.omp.eu/AMDA-NG/public/schemas/spase-amda-1_2_0.xsd">
    <Version>2.2.6</Version>
    <NumericalData>
        <ResourceID>spase://CDPP/NumericalData/AMDA/Rosetta/LAP/ros-lap-efl</ResourceID>
        <ResourceHeader>
            <ResourceName>e-field component (EFL)</ResourceName>
            <AlternateName>Electric field component, calculated on ground by
taking the difference between floating probe measurements on both probes and
ad7a238e   Elena.Budnik   small cor in LAP EFL
10
dividing by distance</AlternateName>
303f2ca9   Elena.Budnik   Rosetta LAP EFL
11
12
13
14
15
16
            <ReleaseDate>2016-10-15T14:08:29Z</ReleaseDate>
            <Description>
The two LAP probes could be used to measure the component of the electric field along their 
separation vector, by measuring the voltage of them, taking the difference and dividing by the 
separation distance (5.0 m). Each probe could be fed by a bias current as is typically done on 
electric field instruments in tenuous plasmas, or be disconnected from the bias circuitry to 
ad7a238e   Elena.Budnik   small cor in LAP EFL
17
ensure a good zero bias current (floating probes) as is typically done on sounding rockets.  
303f2ca9   Elena.Budnik   Rosetta LAP EFL
18
Bias currents were used in the early part of the mission, but when the comet ionosphere 
ad7a238e   Elena.Budnik   small cor in LAP EFL
19
developed, the floating mode was found to give much more consistent data. Only data from 
303f2ca9   Elena.Budnik   Rosetta LAP EFL
20
21
22
the floating mode have been used for providing E-field data, and only when both probes are 
sunlit.

ad7a238e   Elena.Budnik   small cor in LAP EFL
23
24
Positive value refers to electric field  pointing in the direction from probe 1 to probe 2.
 
303f2ca9   Elena.Budnik   Rosetta LAP EFL
25
26
27
The booms are not equal in length (2.24 and 1.62 m) and mounted on a big spacecraft (solar 
panel wingspan 32 m), so one cannot expect LAP to provide a useful DC electric field estimate. 
A moving average of the E-field over 32 s is therefore subtracted from the data in the EFL files. 
ad7a238e   Elena.Budnik   small cor in LAP EFL
28
29
The effective bandwidth of the data therefore is about 0.03 Hz to 20 Hz, the upper 
limit set by the analog anti-aliasing filters. Note that the filtering may distort the lowest 
303f2ca9   Elena.Budnik   Rosetta LAP EFL
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
frequencies. 

There are no external comparison data for assessing the absolute accuracy of the LAP E-field 
measurements. The data themselves look very clean and well behaved [Karlsson et al., 2017; 
André et al, 2017], with very little of common mode signal remaining, despite the s/c poten tial 
being both high and highly variable. The technique with floating probes is proven on numerous 
sounding rockets in the terrestrial ionosphere [Maynard, 1998].
</Description>
            <Contact>       
                <PersonID>spase://CDPP/Person/Anders.Eriksson</PersonID>
                <Role>PrincipalInvestigator</Role>
            </Contact>
            <Contact>       
                <PersonID>spase://CDPP/Person/Erik.Johansson</PersonID>
                <Role>DataProducer</Role>
            </Contact>
            <InformationURL>
                <Name>RPC LAP User Guide</Name>
                <URL>http://amda.irap.omp.eu/help/parameters/RO-IRFU-LAP-UG.PDF</URL>
            </InformationURL> 
            <InformationURL>
                <Name>ROSETTA RPC-LAP to Planetary Science Archive Interface Control Document</Name>
                <URL>http://amda.irap.omp.eu/help/parameters/RO-IRFU-LAP-EAICD_2_0_1_PDF_A.PDF</URL>
            </InformationURL>
        </ResourceHeader>
        <AccessInformation>
            <RepositoryID>spase://SMWG/Repository/CDPP/AMDA</RepositoryID>
            <Availability>Online</Availability>
            <AccessRights>Restricted</AccessRights>
            <AccessURL>
                <URL>http://amda.cdpp.eu</URL>
            </AccessURL>
            <Format>NetCDF</Format>
        </AccessInformation>
        <ProviderName>PSA</ProviderName>  
        <ProviderResourceName>RO-C-RPCLAP-5-xxx-DERIV2-V1.0</ProviderResourceName>
        <InstrumentID>spase://CDPP/Instrument/AMDA/Rosetta/LAP</InstrumentID>
        <MeasurementType>ThermalPlasma</MeasurementType>
        <TemporalDescription>
            <TimeSpan>
                <StartDate>2014-03-24T08:12:59Z</StartDate>
                <StopDate>2016-09-30T10:31:16Z</StopDate>
            </TimeSpan>
            <Cadence_Min>PT0.05S</Cadence_Min>
            <Cadence_Max>PT35S</Cadence_Max>
        </TemporalDescription>
        <Parameter>
            <Name>e-field comp</Name>
            <ParameterKey>ros_lap_efl</ParameterKey>
            <Description>Electric field component, calculated on ground by 
                taking the difference between floating probe measurements on both probes and 
                dividing by distance, (V_P2-V_P1)/L. Positive value refers to electric field 
                pointing in the direction from probe 1 to probe 2.</Description>
            <Ucd/>
            <Units>mV/m</Units>
            <RenderingHints>
                <DisplayType>TimeSeries</DisplayType>
            </RenderingHints>
            <FillValue>-1.e+09</FillValue>
        </Parameter>        
        <Parameter>
            <Name>sampling conf</Name>
            <ParameterKey>ros_lap_efl_s</ParameterKey>
            <Description>Number that describes the exact combination of onboard 
s/w averaging and downsampling. The exact values are pointers into a table 
that describes both the number of samples that are averaged over and the 
downsampling rate</Description>
            <Ucd/>
            <Units/>         
            <RenderingHints>
                <DisplayType>TimeSeries</DisplayType>
            </RenderingHints> 
        </Parameter>
        <Parameter>
            <Name>quality flag</Name>
            <ParameterKey>ros_lap_efl_f</ParameterKey>
            <Description>Quality flag constructed as the sum of multiple terms, 
depending on what quality related effects are present. Each digit is either in 
the range 0 (best) to 7 (worst), or 9 (not used).</Description>
            <Ucd/>
            <Units/>         
            <RenderingHints>
                <DisplayType>TimeSeries</DisplayType>
            </RenderingHints> 
        </Parameter>            
     </NumericalData>
</Spase>