Blame view

Instrument/AMDA/Cluster4/FGM.xml 2.5 KB
d6489ad2   Elena.Budnik   instrument
1
2
3
4
<?xml version="1.0" encoding="UTF-8"?>
<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2_2_6.xsd">
  <Version>2.2.6</Version>
  <Instrument>
6ad90fa5   Elena.Budnik   cluster names modifs
5
    <ResourceID>spase://CDPP/Instrument/AMDA/Cluster4/FGM</ResourceID>
d6489ad2   Elena.Budnik   instrument
6
    <ResourceHeader>
a873e0f6   Elena.Budnik   work
7
8
      <ResourceName>FGM</ResourceName>
      <AlternateName>Fluxgate Magnetometer</AlternateName>
69104870   Elena.Budnik   FGM
9
10
      <ReleaseDate>2016-11-04T15:37:46Z</ReleaseDate>
      <Description>FGM (Fluxgate Magnetometer) consists of two tri-axial fluxgate magnetometers mounted on one of the two 5 m radial booms, plus a data processing unit (DPU) on the main equipment platform. The magnetometer boom lies in the spacecraft spin plane, with the outboard sensor at the boom tip and the inboard sensor mounted 1.5 m inboard from the tip, to minimize the importance of the spacecraft background magnetic field and its variations. The sensors are mounted such that the X axes are aligned with the spacecraft spin axis, and the other axes are in the spin plane. There are five sensitivity ranges, from +/- 256 nT to +/- 65,500 nT (used only to facilitate ground testing). Range switching can be automatic or by command. Calibration is done by introducing a known current step into the feedback loop of the sensors. Telemetry allocation limits the normal output to about 20 vectors/s.</Description>    
d6489ad2   Elena.Budnik   instrument
11
      <Contact>
69104870   Elena.Budnik   FGM
12
        <PersonID>spase://SMWG/Person/Chris.Carr</PersonID>
d6489ad2   Elena.Budnik   instrument
13
14
15
        <Role>PrincipalInvestigator</Role>
      </Contact>
      <InformationURL>
69104870   Elena.Budnik   FGM
16
17
18
19
20
        <Name>ESA web page</Name>
        <URL>http://sci.esa.int/jump.cfm?oid=33024</URL>
        <Description>Fluxgate Magnetometer</Description>
      </InformationURL>
      <InformationURL>
d6489ad2   Elena.Budnik   instrument
21
        <Name>NSSDC's Master Catalog</Name>
69104870   Elena.Budnik   FGM
22
        <URL>http://nssdc.gsfc.nasa.gov/database/MasterCatalog?sc=2000-045A&amp;ex=4</URL>
d6489ad2   Elena.Budnik   instrument
23
24
25
26
27
        <Description>Information about the Fluxgate Magnetometer (FGM) experiment on the Cluster 2/FM8 (Tango) mission.</Description>
      </InformationURL>
      <PriorID>spase://SMWG/Instrument/Cluster2-Tango/FGM</PriorID>
    </ResourceHeader>
    <InstrumentType>Magnetometer</InstrumentType>
69104870   Elena.Budnik   FGM
28
29
30
31
32
    <InvestigationName></InvestigationName>
    <OperatingSpan>
      <StartDate>2000-12-01T00:00:00</StartDate>
      <Note>Start of full orbit coverage: 2002-06-01T00:00:00</Note>
    </OperatingSpan>
6ad90fa5   Elena.Budnik   cluster names modifs
33
    <ObservatoryID>spase://CDPP/Observatory/AMDA/Cluster4</ObservatoryID>
d6489ad2   Elena.Budnik   instrument
34
35
  </Instrument>
</Spase>