Blame view

NumericalData/CDPP-AMDA/ULYSSES/URAP/ulys-urap-dens.xml 6.38 KB
dbc930ab   Elena.Budnik   redmine #7309
1
<?xml version="1.0" encoding="UTF-8"?>
49d48632   Benjamin Renard   cleanup_registry_...
2
3
4
5
6
7
<Spase xmlns="http://www.spase-group.org/data/schema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2.4.1.xsd">
  <Version>2.4.1</Version>
  <NumericalData>
    <ResourceID>spase://CNES/NumericalData/CDPP-AMDA/ULYSSES/URAP/ulys-urap-dens</ResourceID>
    <ResourceHeader>
      <ResourceName>electron density</ResourceName>
0937a8c7   Myriam Bouchemit   Update start/stop...
8
      <ReleaseDate>2012-03-06T22:15:53Z</ReleaseDate>
49d48632   Benjamin Renard   cleanup_registry_...
9
      <Description>The electron density measurements Ne are given in cm-3 and the given acquisition time for each value is dependant on three different measurement methods (flagged by 0,1 or 2). Ne_min and Ne_max stands for errors bars on the density measurements (which are also strongly depending on the measurements methods)
dbc930ab   Elena.Budnik   redmine #7309
10
11
12
13

    The method #0 corresponds to densities deduced from the upper hybrid frequency peak detection, in the HF band of the URAP/RAR receiver (firstly published in Hoang et al., Planet. Space Sci.,Vol. 41, No. 11/12, pp. 1011-1020, 1993, and references therein). The given acquisition time is the elapsed time (UT) of the sweeping receiver at the f_uh peak acquisition.
    The method #1 corresponds to density obtained by the minimum chi-square fitting of theoritical dispersion curves of Bernstein modes to the experimental dispersion curves derived from the URAP/RAR spectra, Ne and Te being the two free fitted parameters (Moncuquet et al., J. Geophys. Res., 100, 21697-21708 , 1995 and references therein); The given acquisition time for each density measurement is the elapsed time (UT) at mid-time of the whole spectrum acquisition (the acquisition duration of a whole spectrum is 128s). In this case, the determination of Ne and Te are synchronized , but they are not independently determined.
    The method #2 corresponds to density obtained from detection of Bernstein "fQ" frequencies (Moncuquet et al.,J. Geophys. Res., 102, 2373-2379, 1997 and references therein). The given acquisition time is the elapsed time (UT) of the sweeping receiver at the lowest fQ acquisition. 
49d48632   Benjamin Renard   cleanup_registry_...
14
15
16
17
18
19
20
21
22
23
24
25
           </Description>
      <Contact>
        <PersonID>spase://SMWG/Person/Elena.Budnik</PersonID>
        <Role>GeneralContact</Role>
      </Contact>
      <Association>
        <AssociationID>uly-urap-lesia</AssociationID>
        <AssociationType>PartOf</AssociationType>
        <Note>io torus QTN</Note>
      </Association>
    </ResourceHeader>
    <AccessInformation>
5fe7a021   Myriam Bouchemit   Update start / st...
26
27
28
29
30
      <RepositoryID>spase://SMWG/Repository/CDPP/AMDA</RepositoryID>
      <Availability>Online</Availability>
      <AccessRights>Open</AccessRights>
      <AccessURL>
        <Name>CDPP/AMDA HAPI Server</Name>
56734b33   Myriam Bouchemit   Update AccessURL ...
31
        <URL>https://amda.irap.omp.eu/service/hapi</URL>
5fe7a021   Myriam Bouchemit   Update start / st...
32
        <Style>HAPI</Style>
56734b33   Myriam Bouchemit   Update AccessURL ...
33
        <ProductKey>ulys-urap-dens</ProductKey>
5fe7a021   Myriam Bouchemit   Update start / st...
34
35
36
        <Description>Web Service to this product using the HAPI interface.</Description>
      </AccessURL>
      <Format>CSV</Format>
56734b33   Myriam Bouchemit   Update AccessURL ...
37
      <Acknowledgement>Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.</Acknowledgement>
5fe7a021   Myriam Bouchemit   Update start / st...
38
    </AccessInformation>
49d48632   Benjamin Renard   cleanup_registry_...
39
    <AccessInformation>
5fe7a021   Myriam Bouchemit   Update start / st...
40
41
42
43
44
      <RepositoryID>spase://SMWG/Repository/CDPP/AMDA</RepositoryID>
      <Availability>Online</Availability>
      <AccessRights>Open</AccessRights>
      <AccessURL>
        <Name>CDPP/AMDA Web application</Name>
56734b33   Myriam Bouchemit   Update AccessURL ...
45
        <URL>https://amda.cdpp.eu</URL>
5fe7a021   Myriam Bouchemit   Update start / st...
46
47
48
49
50
51
        <Description>Access to Data via CDPP/AMDA Web application.</Description>
      </AccessURL>
      <Format>CSV</Format>
      <Format>VOTable</Format>
      <Format>CDF</Format>
      <Format>PNG</Format>
56734b33   Myriam Bouchemit   Update AccessURL ...
52
      <Acknowledgement>Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.</Acknowledgement>
5fe7a021   Myriam Bouchemit   Update start / st...
53
    </AccessInformation>
49d48632   Benjamin Renard   cleanup_registry_...
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
    <ProviderName>LESIA</ProviderName>
    <InstrumentID>spase://CNES/Instrument/CDPP-AMDA/Ulysses/URAP</InstrumentID>
    <MeasurementType>MagneticField</MeasurementType>
    <TemporalDescription>
      <TimeSpan>
        <StartDate>1992-02-08T15:00:28Z</StartDate>
        <StopDate>1992-02-08T22:57:28Z</StopDate>
      </TimeSpan>
      <CadenceMin>PT38S</CadenceMin>
      <CadenceMax>PT576S</CadenceMax>
    </TemporalDescription>
    <ObservedRegion>Jupiter</ObservedRegion>
    <Parameter>
      <Name>density e-</Name>
      <ParameterKey>ulys_urap_ne</ParameterKey>
      <UCD>phys.density;phys.electron</UCD>
      <Units>cm-3</Units>
      <RenderingHints>
        <DisplayType>TimeSeries</DisplayType>
      </RenderingHints>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>NumberDensity</ParticleQuantity>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>density e- min</Name>
      <ParameterKey>ulys_urap_nemin</ParameterKey>
      <UCD>phys.density;phys.electron</UCD>
      <Units>cm-3</Units>
      <RenderingHints>
        <DisplayType>TimeSeries</DisplayType>
      </RenderingHints>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>NumberDensity</ParticleQuantity>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>density e- max</Name>
      <ParameterKey>ulys_urap_nemax</ParameterKey>
      <UCD>phys.density;phys.electron</UCD>
      <Units>cm-3</Units>
      <RenderingHints>
        <DisplayType>TimeSeries</DisplayType>
      </RenderingHints>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>NumberDensity</ParticleQuantity>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>method</Name>
      <ParameterKey>ulys_urap_method</ParameterKey>
      <UCD>meta.code</UCD>
      <RenderingHints>
        <DisplayType>TimeSeries</DisplayType>
      </RenderingHints>
      <Support>
        <SupportQuantity>Other</SupportQuantity>
      </Support>
    </Parameter>
  </NumericalData>
dbc930ab   Elena.Budnik   redmine #7309
117
</Spase>