Blame view

NumericalData/CDPP-AMDA/SWARM-C/TII/swarmc-tii-all.xml 11.2 KB
dbc930ab   Elena.Budnik   redmine #7309
1
<?xml version="1.0" encoding="UTF-8"?>
49d48632   Benjamin Renard   cleanup_registry_...
2
3
4
5
6
7
8
<Spase xmlns="http://www.spase-group.org/data/schema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2.4.1.xsd">
  <Version>2.4.1</Version>
  <NumericalData>
    <ResourceID>spase://CNES/NumericalData/CDPP-AMDA/SWARM-C/TII/swarmc-tii-all</ResourceID>
    <ResourceHeader>
      <ResourceName>cross-track</ResourceName>
      <AlternateName>2Hz TII Cross-track Dataset</AlternateName>
0937a8c7   Myriam Bouchemit   Update start/stop...
9
      <ReleaseDate>2019-05-06T16:55:47Z</ReleaseDate>
d6484f15   Benjamin Renard   Cleanup ToDo flag
10
      <Description>2Hz TII Cross-track Dataset</Description>
49d48632   Benjamin Renard   cleanup_registry_...
11
12
13
14
15
16
17
      <Contact>
        <PersonID>spase://CNES/Person/CDPP-AMDA/Johnathan.Burchill</PersonID>
        <Role>Scientist</Role>
      </Contact>
      <InformationURL>
        <Name>Dataset Description</Name>
        <URL>ftp://swarm-diss.eo.esa.int/Advanced/Plasma_Data/2Hz_TII_Cross-track_Dataset/SW-RN-UoC-GS-004_TIICT_ReleaseNotes.ZIP</URL>
89bb7661   Myriam Bouchemit   Update Start / St...
18
      </InformationURL>
49d48632   Benjamin Renard   cleanup_registry_...
19
20
    </ResourceHeader>
    <AccessInformation>
5fe7a021   Myriam Bouchemit   Update start / st...
21
22
23
24
25
      <RepositoryID>spase://SMWG/Repository/CDPP/AMDA</RepositoryID>
      <Availability>Online</Availability>
      <AccessRights>Open</AccessRights>
      <AccessURL>
        <Name>CDPP/AMDA HAPI Server</Name>
56734b33   Myriam Bouchemit   Update AccessURL ...
26
        <URL>https://amda.irap.omp.eu/service/hapi</URL>
5fe7a021   Myriam Bouchemit   Update start / st...
27
        <Style>HAPI</Style>
56734b33   Myriam Bouchemit   Update AccessURL ...
28
        <ProductKey>swarmc-tii-all</ProductKey>
5fe7a021   Myriam Bouchemit   Update start / st...
29
30
31
        <Description>Web Service to this product using the HAPI interface.</Description>
      </AccessURL>
      <Format>CSV</Format>
56734b33   Myriam Bouchemit   Update AccessURL ...
32
      <Acknowledgement>Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.</Acknowledgement>
5fe7a021   Myriam Bouchemit   Update start / st...
33
    </AccessInformation>
49d48632   Benjamin Renard   cleanup_registry_...
34
    <AccessInformation>
5fe7a021   Myriam Bouchemit   Update start / st...
35
36
37
38
39
      <RepositoryID>spase://SMWG/Repository/CDPP/AMDA</RepositoryID>
      <Availability>Online</Availability>
      <AccessRights>Open</AccessRights>
      <AccessURL>
        <Name>CDPP/AMDA Web application</Name>
56734b33   Myriam Bouchemit   Update AccessURL ...
40
        <URL>https://amda.cdpp.eu</URL>
5fe7a021   Myriam Bouchemit   Update start / st...
41
42
43
44
45
46
        <Description>Access to Data via CDPP/AMDA Web application.</Description>
      </AccessURL>
      <Format>CSV</Format>
      <Format>VOTable</Format>
      <Format>CDF</Format>
      <Format>PNG</Format>
56734b33   Myriam Bouchemit   Update AccessURL ...
47
      <Acknowledgement>Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.</Acknowledgement>
5fe7a021   Myriam Bouchemit   Update start / st...
48
    </AccessInformation>
49d48632   Benjamin Renard   cleanup_registry_...
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
    <ProcessingLevel>Calibrated</ProcessingLevel>
    <ProviderName>ftp://swarm-diss.eo.esa.int</ProviderName>
    <ProviderResourceName>EFI TII Cross-Track Flow Data</ProviderResourceName>
    <ProviderProcessingLevel>Calibrated</ProviderProcessingLevel>
    <InstrumentID>spase://CNES/Instrument/CDPP-AMDA/SWARM-C/TII</InstrumentID>
    <MeasurementType>ElectricField</MeasurementType>
    <TemporalDescription>
      <TimeSpan>
        <StartDate>2015-11-01T17:32:18Z</StartDate>
        <StopDate>2017-12-31T14:00:03Z</StopDate>
      </TimeSpan>
      <Cadence>PT0.5S</Cadence>
    </TemporalDescription>
    <ObservedRegion>Earth.Magnetosphere</ObservedRegion>
    <Caveats> 
dbc930ab   Elena.Budnik   redmine #7309
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
            Data coverage is not continuous. Starting in 2014 EFI TII operations have been limited to a small number of orbits per day. 
            Experience has shown that daily rest periods have the effect of stabilizing the TII imaging performance. 
Effort has been made to remove background levels on an orbital timescale. Significant non-geophysical 
offsets can remain, however, and the TII team urges caution in interpreting flow variations spanning time-scales larger than 
a few to 10s of minutes. Horizontal flow data flagged calibration level 2 are for the most 
part suitable for research and publication. The flagging algorithm 
currently does not perform as well for the vertical flow measurements. The EFI team continues to work on improving the 
flagging algorithm, and solicits and welcomes feedback from the scientific community on the data quality. 
Because along-track flow is assumed to be the satellite speed (~7.6 km/s), real flow variations in the along-track direction  
will appear in the cross-track direction when the angle between the ram flow and the satellite x-axis is non-zero. 
Apparent variations typically not exceeding 100 – 200 m/s in the cross-track flow due 
to large-amplitude along-track flow variations can be expected mainly at high latitudes.

            
            2 Hz ion cross-track flow speed :
            * vy_ion - horizontal flow speed in co-rotating frame. Positive values are to the right, facing forward
            * vz_ion - vertical flow speed in co-rotating frame. Positive values are downward.
            
            * v_corot - Co-rotation signal. Can be added to viy to get approximate horizontal cross-track component of ion velocity in inertial frame of reference.
            Electric field :
            * ex - component parallel to along-track direction in co-rotating frame. Calculated from -vxB assuming along-track ion velocity component is zero
            * ey - component in cross-track horizontal direction in co-rotating frame. Positive values are to the right facing forward. Calculated from -vxB assuming along-track ion velocity component is zero.
            * ez - component in cross-track vertical direction in co-rotating frame. Positive values are downward. Calculated from -vxB assuming along-track ion velocity component is zero.
            Flags :
            Three quality flags are included for each measurement: vy_qual, vz_qual, and e_qual represent approximate data quality 
            for the y and z components of ion velocity and all components of electric field, respectively. Because electric field is derived from 
            both y and z components of ion velocity, qe is effectively the logical ‘AND’ of the other two flags. The flag meanings are as follows :                      
            * -1: ion flow measurements lie outside the nominal measurement range of +- 4 km/s; this encompasses both anomalous measurements and large, geophysical flows.
            * 0: calibration level 0; do not use in scientific publications except for research into TII imaging anomaly, calibration and validation studies.
            * 1: calibration level 1: may contain significant uncorrected biases; the data are often of good quality.
            * 2: calibration level 2: horizontal flows are generally of good quality with reasonable baselines; vertical flows may still contain large variations not of geophysical origin.        
49d48632   Benjamin Renard   cleanup_registry_...
95
96
97
98
        </Caveats>
    <Parameter>
      <Name>v ion</Name>
      <ParameterKey>swc_v_ion</ParameterKey>
49d48632   Benjamin Renard   cleanup_registry_...
99
      <Units>km/s</Units>
49d48632   Benjamin Renard   cleanup_registry_...
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
      <RenderingHints>
        <DisplayType>TimeSeries</DisplayType>
      </RenderingHints>
      <Structure>
        <Size>2</Size>
        <Element>
          <Name>vy</Name>
          <Qualifier>Component.I</Qualifier>
          <Index>1</Index>
          <ParameterKey>swc_v_ion(0)</ParameterKey>
        </Element>
        <Element>
          <Name>vz</Name>
          <Qualifier>Component.J</Qualifier>
          <Index>2</Index>
          <ParameterKey>swc_v_ion(1)</ParameterKey>
        </Element>
      </Structure>
      <Field>
        <Qualifier>Vector</Qualifier>
        <FieldQuantity>Electric</FieldQuantity>
      </Field>
    </Parameter>
    <Parameter>
      <Name>vy quality</Name>
      <ParameterKey>swc_vy_qual</ParameterKey>
49d48632   Benjamin Renard   cleanup_registry_...
126
127
128
129
130
131
132
133
134
135
      <RenderingHints>
        <DisplayType>TimeSeries</DisplayType>
      </RenderingHints>
      <Support>
        <SupportQuantity>DataQuality</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>vz quality</Name>
      <ParameterKey>swc_vz_qual</ParameterKey>
49d48632   Benjamin Renard   cleanup_registry_...
136
137
138
139
140
141
142
143
144
145
146
      <RenderingHints>
        <DisplayType>TimeSeries</DisplayType>
      </RenderingHints>
      <Support>
        <SupportQuantity>DataQuality</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>v corot</Name>
      <ParameterKey>swc_v_corot</ParameterKey>
      <Description>Co-rotation signal. Can be added to viy to get approximate horizontal cross-track component of ion velocity in inertial frame of reference</Description>
49d48632   Benjamin Renard   cleanup_registry_...
147
      <Units>m/s</Units>
49d48632   Benjamin Renard   cleanup_registry_...
148
149
150
      <RenderingHints>
        <DisplayType>TimeSeries</DisplayType>
      </RenderingHints>
49d48632   Benjamin Renard   cleanup_registry_...
151
152
153
154
155
156
157
158
      <Field>
        <FieldQuantity>Electric</FieldQuantity>
      </Field>
    </Parameter>
    <Parameter>
      <Name>e field</Name>
      <ParameterKey>swc_e</ParameterKey>
      <Description>Electric field in co-rotating frame</Description>
49d48632   Benjamin Renard   cleanup_registry_...
159
      <Units>mV/m</Units>
49d48632   Benjamin Renard   cleanup_registry_...
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
      <RenderingHints>
        <DisplayType>TimeSeries</DisplayType>
      </RenderingHints>
      <Structure>
        <Size>3</Size>
        <Element>
          <Name>ex</Name>
          <Qualifier>Component.I</Qualifier>
          <Index>1</Index>
          <ParameterKey>swc_e(0)</ParameterKey>
        </Element>
        <Element>
          <Name>ey</Name>
          <Qualifier>Component.J</Qualifier>
          <Index>2</Index>
          <ParameterKey>swc_e(1)</ParameterKey>
        </Element>
        <Element>
          <Name>ez</Name>
          <Qualifier>Component.K</Qualifier>
          <Index>3</Index>
          <ParameterKey>swc_e(2)</ParameterKey>
        </Element>
      </Structure>
      <Field>
        <Qualifier>Vector</Qualifier>
        <FieldQuantity>Electric</FieldQuantity>
      </Field>
    </Parameter>
    <Parameter>
      <Name>e quality</Name>
      <ParameterKey>swc_e_qual</ParameterKey>
49d48632   Benjamin Renard   cleanup_registry_...
192
      <Units> </Units>
49d48632   Benjamin Renard   cleanup_registry_...
193
194
195
196
197
198
199
200
      <RenderingHints>
        <DisplayType>TimeSeries</DisplayType>
      </RenderingHints>
      <Support>
        <SupportQuantity>DataQuality</SupportQuantity>
      </Support>
    </Parameter>
    <!--<Parameter>
dbc930ab   Elena.Budnik   redmine #7309
201
202
203
            <Name>b field</Name>
            <ParameterKey>swc_b</ParameterKey>
            <Description></Description>
49d48632   Benjamin Renard   cleanup_registry_...
204
            <UCD></UCD>
dbc930ab   Elena.Budnik   redmine #7309
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
            <Units>nT</Units>
            <UnitsConversion></UnitsConversion>           
            <RenderingHints>
                <DisplayType>TimeSeries</DisplayType>
            </RenderingHints> 
             <Structure>
                <Size>3</Size>
                <Element>
                    <Name>bx</Name>
                    <Qualifier>Component.I</Qualifier>
                    <Index>1</Index>
                    <ParameterKey>swc_b(0)</ParameterKey>
                </Element>
                <Element>
                    <Name>by</Name>
                    <Qualifier>Component.J</Qualifier>
                    <Index>2</Index>
                    <ParameterKey>swc_b(1)</ParameterKey>
                </Element>
                <Element>
                    <Name>bz</Name>
                    <Qualifier>Component.K</Qualifier>
                    <Index>3</Index>
                    <ParameterKey>swc_b(2)</ParameterKey> 
                </Element>
            </Structure> 
49d48632   Benjamin Renard   cleanup_registry_...
231
232
        </Parameter>-->
  </NumericalData>
dbc930ab   Elena.Budnik   redmine #7309
233
</Spase>