Blame view

Instrument/CDPP-AMDA/Solar_Orbiter/PAS.xml 2.72 KB
b9cd002f   Elena.Budnik   MEX/VEX IMA; SO PAS
1
<?xml version="1.0" encoding="UTF-8"?>
4b907fdc   Benjamin Renard   cleanup_registry_...
2
3
<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2.4.1.xsd">
  <Version>2.4.1</Version>
b9cd002f   Elena.Budnik   MEX/VEX IMA; SO PAS
4
  <Instrument>
dbc930ab   Elena.Budnik   redmine #7309
5
    <ResourceID>spase://CNES/Instrument/CDPP-AMDA/Solar_Orbiter/PAS</ResourceID>
b9cd002f   Elena.Budnik   MEX/VEX IMA; SO PAS
6
    <ResourceHeader>
348ce0bc   Benjamin Renard   Some fixes
7
      <ResourceName>SWA/PAS</ResourceName>
b9cd002f   Elena.Budnik   MEX/VEX IMA; SO PAS
8
      <AlternateName>Proton-Alpha Sensor</AlternateName>
105f4ac9   Elena.Budnik   Solar Orbiter modifs
9
      <ReleaseDate>2018-10-27T18:45:12Z</ReleaseDate>
4379a412   Benjamin Renard   Add Solar Orbiter...
10
11
12
13
14
15
16
17
18
19
20
21
      <Description>The Proton-Alpha Sensor (PAS) is designed to continuously determine the 3D 
distribution functions of the dominant ions of the solar wind, from 200 eV to 20 KeV, 
without mass and charge selection. In practice, this concerns mostly the proton and alfa 
populations. These measurements are used to calculate the density, speed, pressure 
and temperature tensors of the main component of the solar wind.

At full resolution, PAS measures the 3D ion distribution function, in the form of arrays of 
96 energies, 11  azimuth angles and 9 elevation angles, in about ~1 second. The 
energy and the angle of elevation are selected by imposing different high voltages to 
the electrodes of the deflection system and the electrostatic analyzer. The 11 azimuthal 
angles correspond to the 11 detectors of the instrument (channeltron’).

f5721dfb   Benjamin Renard   Fix quotes in des...
22
In ‘burst‘ mode, the measurement rate can reach up to 20 Hz. The phase space 
4379a412   Benjamin Renard   Add Solar Orbiter...
23
24
25
26
27
28
29
30
31
32
33
sampling is then reduced, for example by 24 energies and 5 deflections, which allows 
to increase the time cadence of distribution functions measurements. An algorithm 
(peak tracking procedure) is used to select the peak of the distribution and to center 
sampling around this peak.

The different types of sampling are programmed in the form of cyclograms. They define 
the operation of the instrument over periods of several days. In normal mode, the 
functions are measured every 4 s with, every 300 s, a short burst mode of 9 s 
(SnapShot). ‘Long’ burst mode is also acquired every day, consisting in 300 s of 
continuous sampling at high cadence. The sampling frequency during burst or 
snapshots is generally of 4 distributions / s (4 Hz analysis).</Description>
b9cd002f   Elena.Budnik   MEX/VEX IMA; SO PAS
34
      <Contact>
105f4ac9   Elena.Budnik   Solar Orbiter modifs
35
        <PersonID>spase://SMWG/Person/Philippe.Louarn</PersonID>
b9cd002f   Elena.Budnik   MEX/VEX IMA; SO PAS
36
        <Role>PrincipalInvestigator</Role>
105f4ac9   Elena.Budnik   Solar Orbiter modifs
37
38
      </Contact> 
      <Contact>
4b907fdc   Benjamin Renard   cleanup_registry_...
39
        <PersonID>spase://CNES/Person/CDPP-AMDA/Andrei.Fedorov</PersonID>
105f4ac9   Elena.Budnik   Solar Orbiter modifs
40
41
        <Role>TechnicalContact</Role>
      </Contact>       
7ad064f4   Benjamin Renard   Cleanup master/am...
42
      </ResourceHeader>
b9cd002f   Elena.Budnik   MEX/VEX IMA; SO PAS
43
44
    <InstrumentType>ParticleDetector</InstrumentType>
    <InvestigationName>SWA</InvestigationName>
d1fe7122   Elena.Budnik   redmine 7309 cont...
45
    <ObservatoryID>spase://CNES/Observatory/CDPP-AMDA/SolO</ObservatoryID>
b9cd002f   Elena.Budnik   MEX/VEX IMA; SO PAS
46
47
  </Instrument>
</Spase>