Blame view

Instrument/CDPP-AMDA/Cluster4/CIS-CODIF.xml 3.16 KB
f82270bb   Elena.Budnik   work
1
<?xml version="1.0" encoding="UTF-8"?>
49d48632   Benjamin Renard   cleanup_registry_...
2
3
<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2.4.1.xsd">
  <Version>2.4.1</Version>
f82270bb   Elena.Budnik   work
4
  <Instrument>
dbc930ab   Elena.Budnik   redmine #7309
5
    <ResourceID>spase://CNES/Instrument/CDPP-AMDA/Cluster4/CIS-CODIF</ResourceID>
f82270bb   Elena.Budnik   work
6
7
8
9
10
11
    <ResourceHeader>
      <ResourceName>CIS-CODIF</ResourceName>
      <AlternateName>Cluster Ion Spectrometry : Composition Distribution Function</AlternateName>
      <ReleaseDate>2011-02-04T15:37:19Z</ReleaseDate>
      <Description>This instrument (CIS: Cluster Ion Spectrometry) is capable of obtaining full 3D ion distributions with high time resolution (in one spacecraft spin) and mass-per-charge resolution. The experiment consists of two different instruments, a Hot Ion Analyzer (HIA) and a time-of-flight Ion Composition and Distribution Function analyzer (CODIF). Extensive on-board processing is done, within its dual-processor Data Processing System (DPS). CODIF determines the distributions of the major ion species with energies from spacecraft potential to 40 KeV/charge with an angular resolution of 22.5 x 10.25 degrees and with two different sensitivities. The CODIF instrument uses electrostatic deflection to select by energy per charge, with subsequent time-of-flight analysis. The sensor primarily covers the energy range 0.02--40 KeV/charge, but with additional pre-acceleration for energies below 25 eV/charge, the range is extended to energies as low as the spacecraft potential. The HIA does not measure mass, but extends the dynamic range to the highest ion fluxes, and has angular resolution capability of 5.6 x 5.6 degrees for ion-beam and solar-wind measurements. The HIA is a symmetric quadrispherical analyzer of top-hat geometry, and uses microchannel-plate electron multipliers and position encoding by discrete anodes. A 2D distribution is obtained once per 62.5 ms, and a full 3D distribution of ions in the energy range ~5 eV/charge to 32 KeV/charge is obtained every 4 s. For more details of the Cluster mission, the spacecraft, and its instruments, see the report ``Cluster: mission, payload and supporting activities,'' March 1993, ESA SP-1159, and the included article ``The Cluster Ion Spectrometry Experiment,'' by H. Reme et al., from which this information was obtained.</Description>
      <Contact>
49d48632   Benjamin Renard   cleanup_registry_...
12
         <PersonID>spase://CNES/Person/CDPP-AMDA/Jannis.Dandouras</PersonID>
f82270bb   Elena.Budnik   work
13
14
15
16
17
18
19
20
21
        <Role>PrincipalInvestigator</Role>
      </Contact>
      <InformationURL>
        <Name>NSSDC's Master Catalog</Name>
        <URL>http://nssdc.gsfc.nasa.gov/database/MasterCatalog?sc=2000-045B&amp;ex=2</URL>
        <Description>Information about the Cluster Ion Spectrometry (CIS) experiment on the Cluster 2/FM8 (Tango) mission.</Description>
      </InformationURL>
      <PriorID>spase://SMWG/Instrument/Cluster2-Tango/CIS</PriorID>
    </ResourceHeader>
71bf18c1   Elena.Budnik   small corrs for C...
22
    <InstrumentType>MassSpectrometer</InstrumentType>
f82270bb   Elena.Budnik   work
23
    <InvestigationName>Cluster Ion Spectrometry (CIS) on Cluster 2/FM8 (Tango)</InvestigationName>
d1fe7122   Elena.Budnik   redmine 7309 cont...
24
    <ObservatoryID>spase://CNES/Observatory/CDPP-AMDA/Cluster4</ObservatoryID>
f82270bb   Elena.Budnik   work
25
26
  </Instrument>
</Spase>